IEC MV, XLPE Insulation, CWS, Lead, ATA, PVC (1C)

Products

1x120

Nexans ref. 21120CXCVEB09DO0

  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 38.0 mm
  • Approximate weight: 3710 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x120

Nexans ref. 21120CXCVEB09EO0

  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 39.0 mm
  • Approximate weight: 3950 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x120

Nexans ref. 21120CXCVEB09GO0

  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 42.0 mm
  • Approximate weight: 4100 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x120

Nexans ref. 21120CXCVEB09HO0

  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 45.0 mm
  • Approximate weight: 4350 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x120

Nexans ref. 21120CXCVEB09JO0

  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 48.0 mm
  • Approximate weight: 5000 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x150

Nexans ref. 21150CXCVEB09DO0

  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 39.0 mm
  • Approximate weight: 4180 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x150

Nexans ref. 21150CXCVEB09EO0

  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 40.0 mm
  • Approximate weight: 4340 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x150

Nexans ref. 21150CXCVEB09GO0

  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 44.0 mm
  • Approximate weight: 4550 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x150

Nexans ref. 21150CXCVEB09HO0

  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 46.0 mm
  • Approximate weight: 4860 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x150

Nexans ref. 21150CXCVEB09JO0

  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 50.0 mm
  • Approximate weight: 5310 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x185

Nexans ref. 21185CXCVEB09DO0

  • Conductor cross-section: 185 mm²
  • Nominal outer diameter: 41.0 mm
  • Approximate weight: 4820 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x185

Nexans ref. 21185CXCVEB09EO0

  • Conductor cross-section: 185 mm²
  • Nominal outer diameter: 42.0 mm
  • Approximate weight: 5150 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x185

Nexans ref. 21185CXCVEB09GO0

  • Conductor cross-section: 185 mm²
  • Nominal outer diameter: 46.0 mm
  • Approximate weight: 5240 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x185

Nexans ref. 21185CXCVEB09HO0

  • Conductor cross-section: 185 mm²
  • Nominal outer diameter: 48.0 mm
  • Approximate weight: 5530 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x185

Nexans ref. 21185CXCVEB09JO0

  • Conductor cross-section: 185 mm²
  • Nominal outer diameter: 53.0 mm
  • Approximate weight: 6400 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x240

Nexans ref. 21240CXCVEB09DO0

  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 45.0 mm
  • Approximate weight: 5940 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x240

Nexans ref. 21240CXCVEB09EO0

  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 46.0 mm
  • Approximate weight: 6160 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x240

Nexans ref. 21240CXCVEB09GO0

  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 48.0 mm
  • Approximate weight: 6230 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x240

Nexans ref. 21240CXCVEB09HO0

  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 52.0 mm
  • Approximate weight: 6535 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x240

Nexans ref. 21240CXCVEB09JO0

  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 57.0 mm
  • Approximate weight: 7330 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x25

Nexans ref. 21025CXCVEB09DO0

  • Conductor cross-section: 25 mm²
  • Nominal outer diameter: 28.0 mm
  • Approximate weight: 1760 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x25

Nexans ref. 21025CXCVEB09EO0

  • Conductor cross-section: 25 mm²
  • Nominal outer diameter: 29.0 mm
  • Approximate weight: 1900 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x25

Nexans ref. 21025CXCVEB09GO0

  • Conductor cross-section: 25 mm²
  • Nominal outer diameter: 32.0 mm
  • Approximate weight: 2070 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x300

Nexans ref. 21300CXCVEB09DO0

  • Conductor cross-section: 300 mm²
  • Nominal outer diameter: 50.0 mm
  • Approximate weight: 6300 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x300

Nexans ref. 21300CXCVEB09EO0

  • Conductor cross-section: 300 mm²
  • Nominal outer diameter: 50.0 mm
  • Approximate weight: 6600 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x300

Nexans ref. 21300CXCVEB09GO0

  • Conductor cross-section: 300 mm²
  • Nominal outer diameter: 52.0 mm
  • Approximate weight: 6800 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x300

Nexans ref. 21300CXCVEB09HO0

  • Conductor cross-section: 300 mm²
  • Nominal outer diameter: 56.0 mm
  • Approximate weight: 7000 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x300

Nexans ref. 21300CXCVEB09JO0

  • Conductor cross-section: 300 mm²
  • Nominal outer diameter: 60.0 mm
  • Approximate weight: 7800 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x35

Nexans ref. 21035CXCVEB09DO0

  • Conductor cross-section: 35 mm²
  • Nominal outer diameter: 29.0 mm
  • Approximate weight: 2020 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x35

Nexans ref. 21035CXCVEB09EO0

  • Conductor cross-section: 35 mm²
  • Nominal outer diameter: 30.0 mm
  • Approximate weight: 2150 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x35

Nexans ref. 21035CXCVEB09GO0

  • Conductor cross-section: 35 mm²
  • Nominal outer diameter: 34.0 mm
  • Approximate weight: 2350 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x35

Nexans ref. 21035CXCVEB09HO0

  • Conductor cross-section: 35 mm²
  • Nominal outer diameter: 36.0 mm
  • Approximate weight: 2540 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x400

Nexans ref. 21400CXCVEB09DO0

  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: 54.0 mm
  • Approximate weight: 7440 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x400

Nexans ref. 21400CXCVEB09EO0

  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: 53.0 mm
  • Approximate weight: 7330 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x400

Nexans ref. 21400CXCVEB09GO0

  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: 59.0 mm
  • Approximate weight: 7880 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x400

Nexans ref. 21400CXCVEB09HO0

  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: 60.0 mm
  • Approximate weight: 8160 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x400

Nexans ref. 21400CXCVEB09JO0

  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: 64.0 mm
  • Approximate weight: 8460 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x50

Nexans ref. 21050CXCVEB09DO0

  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 32.0 mm
  • Approximate weight: 2320 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x50

Nexans ref. 21050CXCVEB09EO0

  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 33.0 mm
  • Approximate weight: 2470 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x50

Nexans ref. 21050CXCVEB09GO0

  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 35.0 mm
  • Approximate weight: 2660 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x50

Nexans ref. 21050CXCVEB09HO0

  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 38.0 mm
  • Approximate weight: 2880 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x50

Nexans ref. 21050CXCVEB09JO0

  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 41.0 mm
  • Approximate weight: 3600 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x500

Nexans ref. 21500CXCVEB09DO0

  • Conductor cross-section: 500 mm²
  • Nominal outer diameter: 59.0 mm
  • Approximate weight: 9375 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x500

Nexans ref. 21500CXCVEB09EO0

  • Conductor cross-section: 500 mm²
  • Nominal outer diameter: 59.0 mm
  • Approximate weight: 9315 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x500

Nexans ref. 21500CXCVEB09GO0

  • Conductor cross-section: 500 mm²
  • Nominal outer diameter: 62.0 mm
  • Approximate weight: 9450 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x500

Nexans ref. 21500CXCVEB09HO0

  • Conductor cross-section: 500 mm²
  • Nominal outer diameter: 64.0 mm
  • Approximate weight: 9765 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x500

Nexans ref. 21500CXCVEB09JO0

  • Conductor cross-section: 500 mm²
  • Nominal outer diameter: 69.0 mm
  • Approximate weight: 10190 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x630

Nexans ref. 21630CXCVEB09DO0

  • Conductor cross-section: 630 mm²
  • Nominal outer diameter: 64.0 mm
  • Approximate weight: 11355 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x630

Nexans ref. 21630CXCVEB09EO0

  • Conductor cross-section: 630 mm²
  • Nominal outer diameter: 64.0 mm
  • Approximate weight: 11280 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x630

Nexans ref. 21630CXCVEB09GO0

  • Conductor cross-section: 630 mm²
  • Nominal outer diameter: 66.0 mm
  • Approximate weight: 11415 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x630

Nexans ref. 21630CXCVEB09HO0

  • Conductor cross-section: 630 mm²
  • Nominal outer diameter: 69.0 mm
  • Approximate weight: 11715 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x630

Nexans ref. 21630CXCVEB09JO0

  • Conductor cross-section: 630 mm²
  • Nominal outer diameter: 72.0 mm
  • Approximate weight: 12218 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x70

Nexans ref. 21070CXCVEB09DO0

  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: 34.0 mm
  • Approximate weight: 2800 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x70

Nexans ref. 21070CXCVEB09EO0

  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: 34.0 mm
  • Approximate weight: 3000 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x70

Nexans ref. 21070CXCVEB09GO0

  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: 38.0 mm
  • Approximate weight: 3180 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x70

Nexans ref. 21070CXCVEB09HO0

  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: 40.0 mm
  • Approximate weight: 3400 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x70

Nexans ref. 21070CXCVEB09JO0

  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: 44.0 mm
  • Approximate weight: 3960 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x800

Nexans ref. 21800CXCVEB09DO0

  • Conductor cross-section: 800 mm²
  • Nominal outer diameter: 70.0 mm
  • Approximate weight: 13950 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x800

Nexans ref. 21800CXCVEB09EO0

  • Conductor cross-section: 800 mm²
  • Nominal outer diameter: 69.0 mm
  • Approximate weight: 13830 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x800

Nexans ref. 21800CXCVEB09GO0

  • Conductor cross-section: 800 mm²
  • Nominal outer diameter: 72.0 mm
  • Approximate weight: 14100 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x800

Nexans ref. 21800CXCVEB09HO0

  • Conductor cross-section: 800 mm²
  • Nominal outer diameter: 75.0 mm
  • Approximate weight: 14410 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x800

Nexans ref. 21800CXCVEB09JO0

  • Conductor cross-section: 800 mm²
  • Nominal outer diameter: 78.0 mm
  • Approximate weight: 14715 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x95

Nexans ref. 21095CXCVEB09DO0

  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 35.0 mm
  • Approximate weight: 3400 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x95

Nexans ref. 21095CXCVEB09EO0

  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 36.0 mm
  • Approximate weight: 3600 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x95

Nexans ref. 21095CXCVEB09GO0

  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 40.0 mm
  • Approximate weight: 3740 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x95

Nexans ref. 21095CXCVEB09HO0

  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 42.0 mm
  • Approximate weight: 4070 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x95

Nexans ref. 21095CXCVEB09JO0

  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 46.0 mm
  • Approximate weight: 4680 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

Description

Description

Standards

  • International
    IEC 60332-1; IEC 60502-2

Application

These power cables are used for electricity supply in medium voltage installation system. They are well adapted to underground use in industrial application where chemical and mechanical protections are needed.
This group is complying with IEC 60502-2.
 

Design

1. Conductor

Stranded bare copper class 2 acc. to IEC 60228 or equivalent

2. Insulation

Triple extruded Inner semi conductive layer  - Cross Linked Polyethylene 'XLPE' - Outer semi conductive layer

3. Metalic Screen

Copper wire screen with open helix copper tape

4. Metalic Sheath

Extruded Lead 

5. Armour

Aluminum Tape Armour "ATA"

6. Outer Sheath

Polyvinyl Chloride 'PVC'

 Options :

      - Flame retardant : 'CAT A, CAT B, CATC' to IEC60332 or equivalent.

      - Ozone resistant.

      - Oil resistant.

      - Anti termite.

Sheathing layers can be Halogen Free Flame Retardant "HFFR", or Polyethylene '"PE'


Installation Conditions:

1.Air Temperature : 30 Deg.

2.Ground Temperature : 20 Deg

3.Soil Thermal Resistivity : 1.5 km/w

4.Depth of lay : 0.8 m

 All dimensions have tolerance +-7 %

Marking

 no. of cores x  conductor size mm2  Cu/XLPE/LS/ATA/PVC  Voltage grade   Standard  MADE IN QATAR  QICC - Nexans  Year  Meters

Custom marking available

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor flexibility
Stranded class 2
Conductor shape
Circular compacted
Material of the inner semi-conductor
Semi-conducting compound
Insulation
XLPE (Cross-linked Polyethylene)
Material of the external semi-conductor
Semi-conducting compound
Screen
Copper wire + copper tape
Inner sheath
PVC
Lead Sheath
Yes
Separator
Tape or sheath
Armour type
Aluminium tape
Outer sheath
PVC compound
Sheath colour
Black

Dimensional characteristics

Dimensional characteristics

Number of cores
1

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

Max. conductor temperature in service
90 °C
Flame retardant
IEC 60332-1
Bending factor when laying
30 (xD)
Bending factor when installed
15 (xD)

Resources

Resources

Selling & delivery Information


Note: On request we are delivering three single core laid up cables on one drum

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close