IEC MV, XLPE Insulation, CWS, Lead, ATA, PVC (1C)
IEC MV, XLPE Insulation, CWS, Lead, ATA, PVC (1C)
Single-core XLPE-insulated cables with PVC sheath
Read more1x120
Nexans ref. 21120CXCVEB09DO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 38.0 mm
- Approximate weight: 3710 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x120
Nexans ref. 21120CXCVEB09EO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 39.0 mm
- Approximate weight: 3950 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x120
Nexans ref. 21120CXCVEB09GO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 42.0 mm
- Approximate weight: 4100 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x120
Nexans ref. 21120CXCVEB09HO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 45.0 mm
- Approximate weight: 4350 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x120
Nexans ref. 21120CXCVEB09JO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 48.0 mm
- Approximate weight: 5000 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x150
Nexans ref. 21150CXCVEB09DO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 39.0 mm
- Approximate weight: 4180 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x150
Nexans ref. 21150CXCVEB09EO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 40.0 mm
- Approximate weight: 4340 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x150
Nexans ref. 21150CXCVEB09GO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 44.0 mm
- Approximate weight: 4550 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x150
Nexans ref. 21150CXCVEB09HO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 46.0 mm
- Approximate weight: 4860 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x150
Nexans ref. 21150CXCVEB09JO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 50.0 mm
- Approximate weight: 5310 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x185
Nexans ref. 21185CXCVEB09DO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 41.0 mm
- Approximate weight: 4820 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x185
Nexans ref. 21185CXCVEB09EO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 42.0 mm
- Approximate weight: 5150 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x185
Nexans ref. 21185CXCVEB09GO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 46.0 mm
- Approximate weight: 5240 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x185
Nexans ref. 21185CXCVEB09HO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 48.0 mm
- Approximate weight: 5530 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x185
Nexans ref. 21185CXCVEB09JO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 53.0 mm
- Approximate weight: 6400 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x240
Nexans ref. 21240CXCVEB09DO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 45.0 mm
- Approximate weight: 5940 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x240
Nexans ref. 21240CXCVEB09EO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 46.0 mm
- Approximate weight: 6160 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x240
Nexans ref. 21240CXCVEB09GO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 48.0 mm
- Approximate weight: 6230 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x240
Nexans ref. 21240CXCVEB09HO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 52.0 mm
- Approximate weight: 6535 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x240
Nexans ref. 21240CXCVEB09JO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 57.0 mm
- Approximate weight: 7330 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x25
Nexans ref. 21025CXCVEB09DO0
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 28.0 mm
- Approximate weight: 1760 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x25
Nexans ref. 21025CXCVEB09EO0
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 29.0 mm
- Approximate weight: 1900 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x25
Nexans ref. 21025CXCVEB09GO0
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 32.0 mm
- Approximate weight: 2070 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x300
Nexans ref. 21300CXCVEB09DO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 50.0 mm
- Approximate weight: 6300 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x300
Nexans ref. 21300CXCVEB09EO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 50.0 mm
- Approximate weight: 6600 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x300
Nexans ref. 21300CXCVEB09GO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 52.0 mm
- Approximate weight: 6800 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x300
Nexans ref. 21300CXCVEB09HO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 56.0 mm
- Approximate weight: 7000 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x300
Nexans ref. 21300CXCVEB09JO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 60.0 mm
- Approximate weight: 7800 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x35
Nexans ref. 21035CXCVEB09DO0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 29.0 mm
- Approximate weight: 2020 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x35
Nexans ref. 21035CXCVEB09EO0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 30.0 mm
- Approximate weight: 2150 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x35
Nexans ref. 21035CXCVEB09GO0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 34.0 mm
- Approximate weight: 2350 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x35
Nexans ref. 21035CXCVEB09HO0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 36.0 mm
- Approximate weight: 2540 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x400
Nexans ref. 21400CXCVEB09DO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 54.0 mm
- Approximate weight: 7440 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x400
Nexans ref. 21400CXCVEB09EO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 53.0 mm
- Approximate weight: 7330 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x400
Nexans ref. 21400CXCVEB09GO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 59.0 mm
- Approximate weight: 7880 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x400
Nexans ref. 21400CXCVEB09HO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 60.0 mm
- Approximate weight: 8160 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x400
Nexans ref. 21400CXCVEB09JO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 64.0 mm
- Approximate weight: 8460 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x50
Nexans ref. 21050CXCVEB09DO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 32.0 mm
- Approximate weight: 2320 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x50
Nexans ref. 21050CXCVEB09EO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 33.0 mm
- Approximate weight: 2470 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x50
Nexans ref. 21050CXCVEB09GO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 35.0 mm
- Approximate weight: 2660 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x50
Nexans ref. 21050CXCVEB09HO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 38.0 mm
- Approximate weight: 2880 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x50
Nexans ref. 21050CXCVEB09JO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 41.0 mm
- Approximate weight: 3600 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x500
Nexans ref. 21500CXCVEB09DO0
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 59.0 mm
- Approximate weight: 9375 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x500
Nexans ref. 21500CXCVEB09EO0
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 59.0 mm
- Approximate weight: 9315 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x500
Nexans ref. 21500CXCVEB09GO0
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 62.0 mm
- Approximate weight: 9450 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x500
Nexans ref. 21500CXCVEB09HO0
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 64.0 mm
- Approximate weight: 9765 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x500
Nexans ref. 21500CXCVEB09JO0
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 69.0 mm
- Approximate weight: 10190 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x630
Nexans ref. 21630CXCVEB09DO0
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 64.0 mm
- Approximate weight: 11355 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x630
Nexans ref. 21630CXCVEB09EO0
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 64.0 mm
- Approximate weight: 11280 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x630
Nexans ref. 21630CXCVEB09GO0
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 66.0 mm
- Approximate weight: 11415 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x630
Nexans ref. 21630CXCVEB09HO0
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 69.0 mm
- Approximate weight: 11715 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x630
Nexans ref. 21630CXCVEB09JO0
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 72.0 mm
- Approximate weight: 12218 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x70
Nexans ref. 21070CXCVEB09DO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 34.0 mm
- Approximate weight: 2800 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x70
Nexans ref. 21070CXCVEB09EO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 34.0 mm
- Approximate weight: 3000 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x70
Nexans ref. 21070CXCVEB09GO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 38.0 mm
- Approximate weight: 3180 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x70
Nexans ref. 21070CXCVEB09HO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 40.0 mm
- Approximate weight: 3400 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x70
Nexans ref. 21070CXCVEB09JO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 44.0 mm
- Approximate weight: 3960 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x800
Nexans ref. 21800CXCVEB09DO0
- Conductor cross-section: 800 mm²
- Nominal outer diameter: 70.0 mm
- Approximate weight: 13950 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x800
Nexans ref. 21800CXCVEB09EO0
- Conductor cross-section: 800 mm²
- Nominal outer diameter: 69.0 mm
- Approximate weight: 13830 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x800
Nexans ref. 21800CXCVEB09GO0
- Conductor cross-section: 800 mm²
- Nominal outer diameter: 72.0 mm
- Approximate weight: 14100 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x800
Nexans ref. 21800CXCVEB09HO0
- Conductor cross-section: 800 mm²
- Nominal outer diameter: 75.0 mm
- Approximate weight: 14410 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x800
Nexans ref. 21800CXCVEB09JO0
- Conductor cross-section: 800 mm²
- Nominal outer diameter: 78.0 mm
- Approximate weight: 14715 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x95
Nexans ref. 21095CXCVEB09DO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 35.0 mm
- Approximate weight: 3400 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x95
Nexans ref. 21095CXCVEB09EO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 36.0 mm
- Approximate weight: 3600 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x95
Nexans ref. 21095CXCVEB09GO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 40.0 mm
- Approximate weight: 3740 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x95
Nexans ref. 21095CXCVEB09HO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 42.0 mm
- Approximate weight: 4070 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x95
Nexans ref. 21095CXCVEB09JO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 46.0 mm
- Approximate weight: 4680 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
Description
Description
Standards
-
InternationalIEC 60332-1; IEC 60502-2
Application
These power cables are used for electricity supply in medium voltage installation system. They are well adapted to underground use in industrial application where chemical and mechanical protections are needed.
This group is complying with IEC 60502-2.
Design
1. Conductor
Stranded bare copper class 2 acc. to IEC 60228 or equivalent
2. Insulation
Triple extruded Inner semi conductive layer - Cross Linked Polyethylene 'XLPE' - Outer semi conductive layer
3. Metalic Screen
Copper wire screen with open helix copper tape
4. Metalic Sheath
Extruded Lead
5. Armour
Aluminum Tape Armour "ATA"
6. Outer Sheath
Polyvinyl Chloride 'PVC'
Options :
- Flame retardant : 'CAT A, CAT B, CATC' to IEC60332 or equivalent.
- Ozone resistant.
- Oil resistant.
- Anti termite.
Sheathing layers can be Halogen Free Flame Retardant "HFFR", or Polyethylene '"PE'
Installation Conditions:
1.Air Temperature : 30 Deg.
2.Ground Temperature : 20 Deg
3.Soil Thermal Resistivity : 1.5 km/w
4.Depth of lay : 0.8 m
All dimensions have tolerance +-7 %
Marking
no. of cores x conductor size mm2 Cu/XLPE/LS/ATA/PVC Voltage grade Standard MADE IN QATAR QICC - Nexans Year Meters
Custom marking available
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Selling & delivery Information
Note: On request we are delivering three single core laid up cables on one drum
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania