IEC 60502-1 HYPRON® Armoured (SWA) Fire retardant
IEC 60502-1 HYPRON® Armoured (SWA) Fire retardant
- 0.6/1 kV Power and control cables
- Lead free
- Armoured with galvanized steel wires (SWA) or aluminium wires (AWA)
- Aliphatic and aromatic hydrocarbons resistant.
IEC 60502-1 HYPRON® Armoured (AWA) 1 x 25
Nexans ref. 10121898
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 1
- Conductor cross-section: 25 mm²
IEC 60502-1 HYPRON® Armoured (AWA) 1 x 35
Nexans ref. 10121899
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 1
- Conductor cross-section: 35 mm²
IEC 60502-1 HYPRON® Armoured (AWA) 1 x 50
Nexans ref. 10121900
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 1
- Conductor cross-section: 50 mm²
IEC 60502-1 HYPRON® Armoured (AWA) 1 x 70
Nexans ref. 10121901
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 1
- Conductor cross-section: 70 mm²
IEC 60502-1 HYPRON® Armoured (AWA) 1 x 95
Nexans ref. 10121902
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 1
- Conductor cross-section: 95 mm²
IEC 60502-1 HYPRON® Armoured (AWA) 1 x 120
Nexans ref. 10121903
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 1
- Conductor cross-section: 120 mm²
IEC 60502-1 HYPRON® Armoured (AWA) 1 x 150
Nexans ref. 10121904
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 1
- Conductor cross-section: 150 mm²
IEC 60502-1 HYPRON® Armoured (AWA) 1 x 185
Nexans ref. 10121905
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 1
- Conductor cross-section: 185 mm²
IEC 60502-1 HYPRON® Armoured (AWA) 1 x 240
Nexans ref. 10121906
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 1
- Conductor cross-section: 240 mm²
IEC 60502-1 HYPRON® Armoured (AWA) 1 x 300
Nexans ref. 10121907
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 1
- Conductor cross-section: 300 mm²
IEC 60502-1 HYPRON® Armoured (AWA) 1 x 400
Nexans ref. 10121908
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 1
- Conductor cross-section: 400 mm²
IEC 60502-1 HYPRON® Armoured (AWA) 1 x 120
Nexans ref.
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 1
- Conductor cross-section: 500 mm²
IEC 60502-1 HYPRON® Armoured (AWA) 1 x 630
Nexans ref.
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 1
- Conductor cross-section: 630 mm²
IEC 60502-1 HYPRON® Armoured (AWA) 1 x 800
Nexans ref.
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 1
- Conductor cross-section: 800 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 2 x 2,5
Nexans ref. 10121911
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- Number of cores: 2
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 2 x 2,5
Nexans ref. 10121914
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 2
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 2 x 4
Nexans ref. 10121915
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- Number of cores: 2
- Conductor cross-section: 4 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 2 x 4
Nexans ref. 10121916
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 2
- Conductor cross-section: 4 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 2 x 6
Nexans ref. 10121917
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 2
- Conductor cross-section: 6 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 2 x 10
Nexans ref. 10121918
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 2
- Conductor cross-section: 10 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 2 x 16
Nexans ref. 10121919
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 2
- Conductor cross-section: 16 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 2 x 25
Nexans ref. 10121920
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 2
- Conductor cross-section: 25 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 2 x 35
Nexans ref. 10121921
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 2
- Conductor cross-section: 35 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 2 x 50
Nexans ref. 10121922
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 2
- Conductor cross-section: 50 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 2 x 70
Nexans ref. 10121923
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 2
- Conductor cross-section: 70 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 2 x 95
Nexans ref. 10121924
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 2
- Conductor cross-section: 95 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 2 x 120
Nexans ref. 10121925
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 2
- Conductor cross-section: 120 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 1,5
Nexans ref. 10121926
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- Number of cores: 3
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 1,5
Nexans ref. 10121927
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 3
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 2,5
Nexans ref. 10121928
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 2,5
Nexans ref. 10121929
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 4
Nexans ref. 10121930
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- Number of cores: 3
- Conductor cross-section: 4 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 4
Nexans ref. 10121931
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 3
- Conductor cross-section: 4 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 6
Nexans ref. 10121932
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 3
- Conductor cross-section: 6 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 10
Nexans ref. 10121933
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 3
- Conductor cross-section: 10 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 16
Nexans ref. 10121935
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 3
- Conductor cross-section: 16 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 25
Nexans ref. 10121936
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 3
- Conductor cross-section: 25 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 35
Nexans ref. 10121937
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 3
- Conductor cross-section: 35 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 50
Nexans ref. 10121938
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 3
- Conductor cross-section: 50 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 70
Nexans ref. 10121939
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 3
- Conductor cross-section: 70 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 95
Nexans ref. 10121940
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 3
- Conductor cross-section: 95 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 120
Nexans ref.
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 3
- Conductor cross-section: 120 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 150
Nexans ref.
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 3
- Conductor cross-section: 150 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 185
Nexans ref.
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 3
- Conductor cross-section: 185 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 240
Nexans ref.
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 3
- Conductor cross-section: 240 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 3 x 300
Nexans ref.
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 3
- Conductor cross-section: 300 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 4 x 1,5
Nexans ref. 10121944
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- Number of cores: 4
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 4 x 1,5
Nexans ref. 10121945
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 4
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 4 x 2,5
Nexans ref. 10121946
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- Number of cores: 4
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 4 x 2,5
Nexans ref. 10121947
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 4
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 4 x 4
Nexans ref. 10121948
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- Number of cores: 4
- Conductor cross-section: 4 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 4 x 4
Nexans ref. 10121949
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 4
- Conductor cross-section: 4 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 4 x 6
Nexans ref. 10121950
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 4
- Conductor cross-section: 6 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 4 x 10
Nexans ref. 10121951
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 4
- Conductor cross-section: 10 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 4 x 16
Nexans ref. 10121952
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 4
- Conductor cross-section: 16 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 4 x 25
Nexans ref. 10121953
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 4
- Conductor cross-section: 25 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 4 x 35
Nexans ref. 10121954
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 4
- Conductor cross-section: 35 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 4 x 50
Nexans ref. 10121955
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 4
- Conductor cross-section: 50 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 4 x 70
Nexans ref. 10121956
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 4
- Conductor cross-section: 70 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 4 x 95
Nexans ref.
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 4
- Conductor cross-section: 95 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 4 x 120
Nexans ref.
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 4
- Conductor cross-section: 120 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 4 x 150
Nexans ref.
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 4
- Conductor cross-section: 150 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 4 x 185
Nexans ref.
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 4
- Conductor cross-section: 185 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 4 x 240
Nexans ref.
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 4
- Conductor cross-section: 240 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 5G 1,5
Nexans ref. 10121957
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- Number of cores: 5
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 5G 1,5
Nexans ref. 10121958
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 5
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 5G 2,5
Nexans ref. 10121959
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- Number of cores: 5
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 5G 2,5
Nexans ref. 10121960
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 5
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 5G 4
Nexans ref. 10121961
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- Number of cores: 5
- Conductor cross-section: 4 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 5G 4
Nexans ref. 10121962
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 5
- Conductor cross-section: 4 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 5G 6
Nexans ref. 10121963
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 5
- Conductor cross-section: 6 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 5G 10
Nexans ref. 10121964
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 5
- Conductor cross-section: 10 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 5G 16
Nexans ref. 10121965
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 5
- Conductor cross-section: 16 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 5G 25
Nexans ref. 10121966
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 5
- Conductor cross-section: 25 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 5G 35
Nexans ref. 10121967
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 5
- Conductor cross-section: 35 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 5G 50
Nexans ref. 10121968
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 5
- Conductor cross-section: 50 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 5 G 70
Nexans ref.
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 5
- Conductor cross-section: 70 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 5 G 95
Nexans ref.
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 5
- Conductor cross-section: 95 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 5 G 120
Nexans ref.
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 5
- Conductor cross-section: 120 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 5 G 150
Nexans ref.
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 5
- Conductor cross-section: 150 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 5 G 185
Nexans ref.
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 5
- Conductor cross-section: 185 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 7 x 1,5
Nexans ref. 10121969
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 7
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 7 x 2,5
Nexans ref. 10121978
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 7
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 10 x 1,5
Nexans ref. 10121970
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 10
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 10 x 2,5
Nexans ref. 10121979
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 10
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 12 x 1,5
Nexans ref. 10121971
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 12
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 12 x 2,5
Nexans ref. 10121980
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 12
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 14 x1,5
Nexans ref. 10121972
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 14
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 14 x 2,5
Nexans ref. 10121981
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 14
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 19 x 1,5
Nexans ref. 10121973
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 19
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 19 x 2,5
Nexans ref. 10121982
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 19
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 24 x 1,5
Nexans ref. 10121974
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 24
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 24 x 2,5
Nexans ref. 10121983
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 24
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 27 x 1,5
Nexans ref. 10121975
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 27
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 27 x 2,5
Nexans ref. 10121984
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 27
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 30 x 1,5
Nexans ref. 10121976
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 30
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 30 x 2,5
Nexans ref. 10121985
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 30
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 37 x 1,5
Nexans ref. 10121977
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 37
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Armoured (SWA) 37 x 2,5
Nexans ref. 10121986
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- Number of cores: 37
- Conductor cross-section: 2.5 mm²
Description
Description
Standards
-
InternationalIEC 60228; IEC 60332-3-22 Cat.A
Applications
These power and control cables are used for electricity supply in low voltage installation system, in moist areas and where aliphatic and aromatic hydrocarbons may be present. They are well adapted to underground use in industrial applications where chemical and mechanical protections are needed (refinery areas, chemical plant...). Hypron® offers an alternative to conventional lead covered cable and is an environmental friendly solution.
Design
Conductor
- Solid plain copper: 1.5 to 4 mm²
- Stranded plain copper: 1.5 to 630 mm²
Insulation:
- Cross-linked polyethylene (XLPE)
Assembling (optional):
- Inner sheath acting as a filler with practically zero thickness
or
- Assembling polyester tape
Screen/sealing barrier:
- Tinned copper drain wire,
- Aluminium/polyethylene tape
Inner sheath:
- High density polyethylene (HDPE)
- Colour: black
Special sheath: (intermediate sheath)
- Polyamide
Armour:
- Galvanized steel wires (SWA)
or
- Aluminium wires (AWA) for 1 core cable
Outer sheath:
- Polyvinyl chloride (PVC)
Colour : black. Other colour on request.
Core identification
1 core: black
2x to 5G cores: according to HD 308 S2
Above 5 cores: black core printed with white number
Marking
NEXANS 279 XLPE/AL/HDPE/NC/AWA or SWA/PVC 0.6/1 kV Nber of cores and cross-section Cu IEC 60332-3-22(A) MM YYYY manufacturing number + meter marking
IEC 60502-1 (design guide-lines)
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Selling & delivery Information
Other fire performances IEC 60332-1 or IEC 60332-3-24(C) on request.
Minimum bending radius:
10 x outer diameter
To be doubled during laying operations
Cables with reduced neutral on request