IEC MV, XLPE Insulation, CTS, Lead, PVC (1C)
IEC MV, XLPE Insulation, CTS, Lead, PVC (1C)
Single-core XLPE-insulated cables with PVC sheath
Read more1x120
Nexans ref. 21120CXTVUB09DO0
- Approximate weight: 2440 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x120
Nexans ref. 21120CXTVUB09EO0
- Approximate weight: 2700 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x120
Nexans ref. 21120CXTVUB09GO0
- Approximate weight: 2900 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x120
Nexans ref. 21120CXTVUB09HO0
- Approximate weight: 3100 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x120
Nexans ref. 21120CXTVUB09JO0
- Approximate weight: 3410 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x150
Nexans ref. 21150CXTVUB09DO0
- Approximate weight: 2910 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x150
Nexans ref. 21150CXTVUB09EO0
- Approximate weight: 3040 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x150
Nexans ref. 21150CXTVUB09GO0
- Approximate weight: 3260 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x150
Nexans ref. 21150CXTVUB09HO0
- Approximate weight: 3440 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x150
Nexans ref. 21150CXTVUB09JO0
- Approximate weight: 3930 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x185
Nexans ref. 21185CXTVUB09DO0
- Approximate weight: 3380 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x185
Nexans ref. 21185CXTVUB09EO0
- Approximate weight: 3580 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x185
Nexans ref. 21185CXTVUB09GO0
- Approximate weight: 3770 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x185
Nexans ref. 21185CXTVUB09HO0
- Approximate weight: 3950 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x185
Nexans ref. 21185CXTVUB09JO0
- Approximate weight: 4730 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x240
Nexans ref. 21240CXTVUB09DO0
- Approximate weight: 3700 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x240
Nexans ref. 21240CXTVUB09EO0
- Approximate weight: 3900 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x240
Nexans ref. 21240CXTVUB09GO0
- Approximate weight: 4100 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x240
Nexans ref. 21240CXTVUB09HO0
- Approximate weight: 4300 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x240
Nexans ref. 21240CXTVUB09JO0
- Approximate weight: 5000 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x25
Nexans ref. 21025CXTVUB09DO0
- Approximate weight: 1230 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x25
Nexans ref. 21025CXTVUB09EO0
- Approximate weight: 1345 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x25
Nexans ref. 21025CXTVUB09GO0
- Approximate weight: 1475 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x300
Nexans ref. 21300CXTVUB09DO0
- Approximate weight: 4150 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x300
Nexans ref. 21300CXTVUB09EO0
- Approximate weight: 4230 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x300
Nexans ref. 21300CXTVUB09GO0
- Approximate weight: 4410 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x300
Nexans ref. 21300CXTVUB09HO0
- Approximate weight: 4740 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x300
Nexans ref. 21300CXTVUB09JO0
- Approximate weight: 5280 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x35
Nexans ref. 21035CXTVUB09DO0
- Approximate weight: 1400 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x35
Nexans ref. 21035CXTVUB09EO0
- Approximate weight: 1500 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x35
Nexans ref. 21035CXTVUB09GO0
- Approximate weight: 1670 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x35
Nexans ref. 21035CXTVUB09HO0
- Approximate weight: 1820 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x400
Nexans ref. 21400CXTVUB09DO0
- Approximate weight: 5200 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x400
Nexans ref. 21400CXTVUB09EO0
- Approximate weight: 5190 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x400
Nexans ref. 21400CXTVUB09GO0
- Approximate weight: 5635 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x400
Nexans ref. 21400CXTVUB09HO0
- Approximate weight: 5830 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x400
Nexans ref. 21400CXTVUB09JO0
- Approximate weight: 6250 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x50
Nexans ref. 21050CXTVUB09DO0
- Approximate weight: 1615 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x50
Nexans ref. 21050CXTVUB09EO0
- Approximate weight: 1730 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x50
Nexans ref. 21050CXTVUB09GO0
- Approximate weight: 1900 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x50
Nexans ref. 21050CXTVUB09HO0
- Approximate weight: 2060 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x50
Nexans ref. 21050CXTVUB09JO0
- Approximate weight: 2660 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x500
Nexans ref. 21500CXTVUB09DO0
- Approximate weight: 6545 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x500
Nexans ref. 21500CXTVUB09EO0
- Approximate weight: 6580 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x500
Nexans ref. 21500CXTVUB09GO0
- Approximate weight: 6755 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x500
Nexans ref. 21500CXTVUB09HO0
- Approximate weight: 6980 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x500
Nexans ref. 21500CXTVUB09JO0
- Approximate weight: 7530 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x630
Nexans ref. 21630CXTVUB09DO0
- Approximate weight: 7930 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x630
Nexans ref. 21630CXTVUB09EO0
- Approximate weight: 7980 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x630
Nexans ref. 21630CXTVUB09GO0
- Approximate weight: 8160 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x630
Nexans ref. 21630CXTVUB09HO0
- Approximate weight: 8380 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x630
Nexans ref. 21630CXTVUB09JO0
- Approximate weight: 9030 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x70
Nexans ref. 21070CXTVUB09DO0
- Approximate weight: 1960 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x70
Nexans ref. 21070CXTVUB09EO0
- Approximate weight: 2090 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x70
Nexans ref. 21070CXTVUB09GO0
- Approximate weight: 2270 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x70
Nexans ref. 21070CXTVUB09HO0
- Approximate weight: 2430 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x70
Nexans ref. 21070CXTVUB09JO0
- Approximate weight: 2925 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x800
Nexans ref. 21800CXTVUB09DO0
- Approximate weight: 9745 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x800
Nexans ref. 21800CXTVUB09EO0
- Approximate weight: 9785 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x800
Nexans ref. 21800CXTVUB09GO0
- Approximate weight: 10075 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x800
Nexans ref. 21800CXTVUB09HO0
- Approximate weight: 10310 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x800
Nexans ref. 21800CXTVUB09JO0
- Approximate weight: 10875 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x95
Nexans ref. 21095CXTVUB09DO0
- Approximate weight: 2360 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x95
Nexans ref. 21095CXTVUB09EO0
- Approximate weight: 2500 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x95
Nexans ref. 21095CXTVUB09GO0
- Approximate weight: 2670 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x95
Nexans ref. 21095CXTVUB09HO0
- Approximate weight: 2911 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x95
Nexans ref. 21095CXTVUB09JO0
- Approximate weight: 3460 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
Description
Description
Standards
-
InternationalIEC 60332-1; IEC 60502-2
Application
These power cables are used for electricity supply in medium voltage installation system. They are well adapted to underground use in industrial application where chemical and mechanical protections are needed.
This group is complying with IEC 60502-2.
Design
1. Conductor
Stranded bare copper class 2 acc. to IEC 60228 or equivalent
2. Insulation
Triple extruded Inner semi conductive layer - Cross Linked Polyethylene 'XLPE' - Outer semi conductive layer
3. Metalic Screen
Copper tape screen
4. Metalic Sheath
Extruded Lead
5. Outer Sheath
Polyvinyl Chloride 'PVC'
Options :
- Flame retardant : 'CAT A, CAT B, CATC' to IEC60332 or equivalent.
- Ozone resistant.
- Oil resistant.
- Anti termite.
Sheathing layers can be Halogen Free Flame Retardant "HFFR", or Polyethylene '"PE'
Installation Conditions:
1.Air Temperature : 30 Deg.
2.Ground Temperature : 20 Deg
3.Soil Thermal Resistivity : 1.5 km/w
4.Depth of lay : 0.8 m
All dimensions have tolerance +-7 %
Marking
no. of cores x conductor size mm2 Cu/XLPE/LS/PVC Voltage grade Standard MADE IN QATAR QICC - Nexans Year Meters
Custom marking available
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Selling & delivery Information
Note: On request we are delivering three single core laid up cables on one drum
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania