IEC MV, XLPE Insulation, CWS, Lead, AWA, PVC (1C)
IEC MV, XLPE Insulation, CWS, Lead, AWA, PVC (1C)
Single-core XLPE-insulated cables with PVC sheath
Read more1x120
Nexans ref. 21120CXCVAB09DO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 37.0 mm
- Approximate weight: 3800 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x120
Nexans ref. 21120CXCVAB09EO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 40.0 mm
- Approximate weight: 3950 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x120
Nexans ref. 21120CXCVAB09GO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 43.0 mm
- Approximate weight: 4250 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x120
Nexans ref. 21120CXCVAB09HO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 45.0 mm
- Approximate weight: 4600 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x120
Nexans ref. 21120CXCVAB09JO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 51.0 mm
- Approximate weight: 5130 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x150
Nexans ref. 21150CXCVAB09DO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 38.0 mm
- Approximate weight: 4370 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x150
Nexans ref. 21150CXCVAB09EO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 41.0 mm
- Approximate weight: 4570 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x150
Nexans ref. 21150CXCVAB09GO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 44.0 mm
- Approximate weight: 4895 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x150
Nexans ref. 21150CXCVAB09HO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 46.0 mm
- Approximate weight: 5170 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x150
Nexans ref. 21150CXCVAB09JO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 52.0 mm
- Approximate weight: 5910 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x185
Nexans ref. 21185CXCVAB09DO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 41.0 mm
- Approximate weight: 5080 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x185
Nexans ref. 21185CXCVAB09EO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 43.0 mm
- Approximate weight: 5390 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x185
Nexans ref. 21185CXCVAB09GO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 46.0 mm
- Approximate weight: 5670 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x185
Nexans ref. 21185CXCVAB09HO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 49.0 mm
- Approximate weight: 5940 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x185
Nexans ref. 21185CXCVAB09JO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 56.0 mm
- Approximate weight: 7110 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x240
Nexans ref. 21240CXCVAB09DO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 45.0 mm
- Approximate weight: 5500 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x240
Nexans ref. 21240CXCVAB09EO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 48.0 mm
- Approximate weight: 5800 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x240
Nexans ref. 21240CXCVAB09GO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 50.0 mm
- Approximate weight: 6100 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x240
Nexans ref. 21240CXCVAB09HO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 54.0 mm
- Approximate weight: 6600 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x240
Nexans ref. 21240CXCVAB09JO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 61.0 mm
- Approximate weight: 7000 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x25
Nexans ref. 21025CXCVAB09DO0
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 28.0 mm
- Approximate weight: 1850 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x25
Nexans ref. 21025CXCVAB09EO0
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 30.0 mm
- Approximate weight: 2020 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x25
Nexans ref. 21025CXCVAB09GO0
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 33.0 mm
- Approximate weight: 2220 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x300
Nexans ref. 21300CXCVAB09DO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 50.0 mm
- Approximate weight: 6240 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x300
Nexans ref. 21300CXCVAB09EO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 51.0 mm
- Approximate weight: 6360 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x300
Nexans ref. 21300CXCVAB09GO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 54.0 mm
- Approximate weight: 6630 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x300
Nexans ref. 21300CXCVAB09HO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 57.0 mm
- Approximate weight: 7125 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x300
Nexans ref. 21300CXCVAB09JO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 64.0 mm
- Approximate weight: 7935 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x35
Nexans ref. 21035CXCVAB09DO0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 29.0 mm
- Approximate weight: 2100 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x35
Nexans ref. 21035CXCVAB09EO0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 32.0 mm
- Approximate weight: 2260 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x35
Nexans ref. 21035CXCVAB09GO0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 35.0 mm
- Approximate weight: 2520 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x35
Nexans ref. 21035CXCVAB09HO0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 37.0 mm
- Approximate weight: 2740 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x400
Nexans ref. 21400CXCVAB09DO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 55.0 mm
- Approximate weight: 7815 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x400
Nexans ref. 21400CXCVAB09EO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 55.0 mm
- Approximate weight: 7800 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x400
Nexans ref. 21400CXCVAB09GO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 61.0 mm
- Approximate weight: 8475 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x400
Nexans ref. 21400CXCVAB09HO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 62.0 mm
- Approximate weight: 8775 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x400
Nexans ref. 21400CXCVAB09JO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 68.0 mm
- Approximate weight: 9405 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x50
Nexans ref. 21050CXCVAB09DO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 32.0 mm
- Approximate weight: 2430 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x50
Nexans ref. 21050CXCVAB09EO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 34.0 mm
- Approximate weight: 2600 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x50
Nexans ref. 21050CXCVAB09GO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 36.0 mm
- Approximate weight: 2860 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x50
Nexans ref. 21050CXCVAB09HO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 38.0 mm
- Approximate weight: 3100 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x50
Nexans ref. 21050CXCVAB09JO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 44.0 mm
- Approximate weight: 4000 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x500
Nexans ref. 21500CXCVAB09DO0
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 59.0 mm
- Approximate weight: 9840 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x500
Nexans ref. 21500CXCVAB09EO0
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 61.0 mm
- Approximate weight: 9900 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x500
Nexans ref. 21500CXCVAB09GO0
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 63.0 mm
- Approximate weight: 10155 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x500
Nexans ref. 21500CXCVAB09HO0
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 65.0 mm
- Approximate weight: 10500 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x500
Nexans ref. 21500CXCVAB09JO0
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 72.0 mm
- Approximate weight: 11325 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x630
Nexans ref. 21630CXCVAB09DO0
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 64.0 mm
- Approximate weight: 11925 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x630
Nexans ref. 21630CXCVAB09EO0
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 65.0 mm
- Approximate weight: 12000 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x630
Nexans ref. 21630CXCVAB09GO0
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 68.0 mm
- Approximate weight: 12270 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x630
Nexans ref. 21630CXCVAB09HO0
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 70.0 mm
- Approximate weight: 12600 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x630
Nexans ref. 21630CXCVAB09JO0
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 76.0 mm
- Approximate weight: 13575 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x70
Nexans ref. 21070CXCVAB09DO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 34.0 mm
- Approximate weight: 2950 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x70
Nexans ref. 21070CXCVAB09EO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 35.0 mm
- Approximate weight: 3140 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x70
Nexans ref. 21070CXCVAB09GO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 38.0 mm
- Approximate weight: 3420 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x70
Nexans ref. 21070CXCVAB09HO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 41.0 mm
- Approximate weight: 3660 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x70
Nexans ref. 21070CXCVAB09JO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 46.0 mm
- Approximate weight: 4400 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x800
Nexans ref. 21800CXCVAB09DO0
- Conductor cross-section: 800 mm²
- Nominal outer diameter: 70.0 mm
- Approximate weight: 14663 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x800
Nexans ref. 21800CXCVAB09EO0
- Conductor cross-section: 800 mm²
- Nominal outer diameter: 70.0 mm
- Approximate weight: 14715 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x800
Nexans ref. 21800CXCVAB09GO0
- Conductor cross-section: 800 mm²
- Nominal outer diameter: 74.0 mm
- Approximate weight: 15150 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x800
Nexans ref. 21800CXCVAB09HO0
- Conductor cross-section: 800 mm²
- Nominal outer diameter: 76.0 mm
- Approximate weight: 15495 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x800
Nexans ref. 21800CXCVAB09JO0
- Conductor cross-section: 800 mm²
- Nominal outer diameter: 82.0 mm
- Approximate weight: 16350 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x95
Nexans ref. 21095CXCVAB09DO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 35.0 mm
- Approximate weight: 3550 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x95
Nexans ref. 21095CXCVAB09EO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 37.0 mm
- Approximate weight: 3760 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x95
Nexans ref. 21095CXCVAB09GO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 41.0 mm
- Approximate weight: 4020 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x95
Nexans ref. 21095CXCVAB09HO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 43.0 mm
- Approximate weight: 4380 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x95
Nexans ref. 21095CXCVAB09JO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 49.0 mm
- Approximate weight: 5200 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
Description
Description
Standards
-
ProductIEC 60502-2
-
TestIEC 60332-1
Application
These power cables are used for electricity supply in medium voltage installation system. They are well adapted to underground use in industrial application where chemical and mechanical protections are needed.
This group is complying with IEC 60502-2 or BS 6622.
Design
1. Conductor
Stranded bare copper class 2 acc. to IEC 60228 or equivalent
2. Insulation
Triple extruded Inner semi conductive layer - Cross Linked Polyethylene 'XLPE' - Outer semi conductive layer
3. Metalic Screen
Copper wire screen with open helix copper tape
4. Metalic Sheath
Extruded Lead
5. Armour
Aluminum Wire Armour "AWA"
6. Outer Sheath
Polyvinyl Chloride 'PVC'
Options :
- Flame retardant : 'CAT A, CAT B, CATC' to IEC60332 or equivalent.
- Ozone resistant.
- Oil resistant.
- Anti termite.
Sheathing layers can be Halogen Free Flame Retardant "HFFR", or Polyethylene '"PE'
Installation Conditions:
1.Air Temperature : 30 Deg.
2.Ground Temperature : 20 Deg
3.Soil Thermal Resistivity : 1.5 km/w
4.Depth of lay : 0.8 m
All dimensions have tolerance +-7 %
Marking
no. of cores x conductor size mm2 Cu/XLPE/LS/AWA/PVC Voltage grade Standard MADE IN QATAR QICC - Nexans Year Meters
Custom marking available
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Selling & delivery Information
Note: On request we are delivering three single core laid up cables on one drum
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania