IEC/BS MV, XLPE Insulation, CTS, PVC (3C)
IEC/BS MV, XLPE Insulation, CTS, PVC (3C)
Multi-core XLPE-insulated cables with PVC sheath
Read more3x120
Nexans ref. 23120CXTVUB09DD0
- Conductor cross-section: 120 mm²
- Approximate weight: 5100 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x120
Nexans ref. 23120CXTVUB09ED0
- Conductor cross-section: 120 mm²
- Approximate weight: 5430 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x120
Nexans ref. 23120CXTVUB09GD0
- Conductor cross-section: 120 mm²
- Approximate weight: 5885 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x120
Nexans ref. 23120CXTVUB09HD0
- Conductor cross-section: 120 mm²
- Approximate weight: 6300 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x120
Nexans ref. 23120CXTVUB09JD0
- Conductor cross-section: 120 mm²
- Approximate weight: 8015 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x150
Nexans ref. 23150CXTVUB09DD0
- Conductor cross-section: 150 mm²
- Approximate weight: 6020 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x150
Nexans ref. 23150CXTVUB09ED0
- Conductor cross-section: 150 mm²
- Approximate weight: 6400 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x150
Nexans ref. 23150CXTVUB09GD0
- Conductor cross-section: 150 mm²
- Approximate weight: 6840 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x150
Nexans ref. 23150CXTVUB09HD0
- Conductor cross-section: 150 mm²
- Approximate weight: 7995 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x150
Nexans ref. 23150CXTVUB09JD0
- Conductor cross-section: 150 mm²
- Approximate weight: 9140 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x185
Nexans ref. 23185CXTVUB09DD0
- Conductor cross-section: 185 mm²
- Approximate weight: 7270 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x185
Nexans ref. 23185CXTVUB09ED0
- Conductor cross-section: 185 mm²
- Approximate weight: 7660 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x185
Nexans ref. 23185CXTVUB09GD0
- Conductor cross-section: 185 mm²
- Approximate weight: 8885 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x185
Nexans ref. 23185CXTVUB09HD0
- Conductor cross-section: 185 mm²
- Approximate weight: 9410 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x185
Nexans ref. 23185CXTVUB09JD0
- Conductor cross-section: 185 mm²
- Approximate weight: 10620 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x240
Nexans ref. 23240CXTVUB09DD0
- Conductor cross-section: 240 mm²
- Approximate weight: 8720 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x240
Nexans ref. 23240CXTVUB09ED0
- Conductor cross-section: 240 mm²
- Approximate weight: 9840 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x240
Nexans ref. 23240CXTVUB09GD0
- Conductor cross-section: 240 mm²
- Approximate weight: 10415 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x240
Nexans ref. 23240CXTVUB09HD0
- Conductor cross-section: 240 mm²
- Approximate weight: 10940 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x240
Nexans ref. 23240CXTVUB09JD0
- Conductor cross-section: 240 mm²
- Approximate weight: 12140 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x25
Nexans ref. 23025CXTVUB09DD0
- Conductor cross-section: 25 mm²
- Approximate weight: 1730 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x25
Nexans ref. 23025CXTVUB09ED0
- Conductor cross-section: 25 mm²
- Approximate weight: 2150 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x25
Nexans ref. 23025CXTVUB09GD0
- Conductor cross-section: 25 mm²
- Approximate weight: 2470 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x300
Nexans ref. 23300CXTVUB09DD0
- Conductor cross-section: 300 mm²
- Approximate weight: 11420 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x300
Nexans ref. 23300CXTVUB09ED0
- Conductor cross-section: 300 mm²
- Approximate weight: 11775 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x300
Nexans ref. 23300CXTVUB09GD0
- Conductor cross-section: 300 mm²
- Approximate weight: 12335 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x300
Nexans ref. 23300CXTVUB09HD0
- Conductor cross-section: 300 mm²
- Approximate weight: 12780 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x300
Nexans ref. 23300CXTVUB09JD0
- Conductor cross-section: 300 mm²
- Approximate weight: 14090 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x35
Nexans ref. 23035CXTVUB09DD0
- Conductor cross-section: 35 mm²
- Approximate weight: 1970 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x35
Nexans ref. 23035CXTVUB09ED0
- Conductor cross-section: 35 mm²
- Approximate weight: 2440 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x35
Nexans ref. 23035CXTVUB09GD0
- Conductor cross-section: 35 mm²
- Approximate weight: 2705 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x35
Nexans ref. 23035CXTVUB09HD0
- Conductor cross-section: 35 mm²
- Approximate weight: 3030 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x400
Nexans ref. 23400CXTVUB09DD0
- Conductor cross-section: 400 mm²
- Approximate weight: 13960 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x400
Nexans ref. 23400CXTVUB09ED0
- Conductor cross-section: 400 mm²
- Approximate weight: 14160 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x400
Nexans ref. 23400CXTVUB09GD0
- Conductor cross-section: 400 mm²
- Approximate weight: 14650 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x400
Nexans ref. 23400CXTVUB09HD0
- Conductor cross-section: 400 mm²
- Approximate weight: 15115 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x400
Nexans ref. 23400CXTVUB09JD0
- Conductor cross-section: 400 mm²
- Approximate weight: 16220 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x50
Nexans ref. 23050CXTVUB09DD0
- Conductor cross-section: 50 mm²
- Approximate weight: 2515 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x50
Nexans ref. 23050CXTVUB09ED0
- Conductor cross-section: 50 mm²
- Approximate weight: 2760 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x50
Nexans ref. 23050CXTVUB09GD0
- Conductor cross-section: 50 mm²
- Approximate weight: 3040 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x50
Nexans ref. 23050CXTVUB09HD0
- Conductor cross-section: 50 mm²
- Approximate weight: 3380 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x50
Nexans ref. 23050CXTVUB09JD0
- Conductor cross-section: 50 mm²
- Approximate weight: 4605 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x70
Nexans ref. 23070CXTVUB09DD0
- Conductor cross-section: 70 mm²
- Approximate weight: 3360 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x70
Nexans ref. 23070CXTVUB09ED0
- Conductor cross-section: 70 mm²
- Approximate weight: 3630 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x70
Nexans ref. 23070CXTVUB09GD0
- Conductor cross-section: 70 mm²
- Approximate weight: 4015 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x70
Nexans ref. 23070CXTVUB09HD0
- Conductor cross-section: 70 mm²
- Approximate weight: 4345 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x70
Nexans ref. 23070CXTVUB09JD0
- Conductor cross-section: 70 mm²
- Approximate weight: 5860 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x95
Nexans ref. 23095CXTVUB09DD0
- Conductor cross-section: 95 mm²
- Approximate weight: 3975 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x95
Nexans ref. 23095CXTVUB09ED0
- Conductor cross-section: 95 mm²
- Approximate weight: 4010 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x95
Nexans ref. 23095CXTVUB09GD0
- Conductor cross-section: 95 mm²
- Approximate weight: 4670 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x95
Nexans ref. 23095CXTVUB09HD0
- Conductor cross-section: 95 mm²
- Approximate weight: 5050 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x95
Nexans ref. 23095CXTVUB09JD0
- Conductor cross-section: 95 mm²
- Approximate weight: 6550 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
Description
Description
Standards
-
InternationalIEC 60332-1; IEC 60502-2
-
NationalBS 6622
Application
These power cables are used for electricity supply in medium voltage installation system. They are well adapted to underground use in industrial application where chemical and mechanical protections are needed. This group is complying with IEC 60502-2 or BS 6622.
Design
1. Conductor
Stranded bare copper class 2 acc. to IEC 60228 or equivalent
2. Insulation
Triple extruded Inner semi conductive layer - Cross Linked Polyethylene 'XLPE' - Outer semi conductive layer
3. Metalic Screen
Copper tape screen
4. Inner Sheathing or Bedding
Extruded PVC
5. Outer Sheath
Polyvinyl Chloride 'PVC'
Options :
- Flame retardant : 'CAT A, CAT B, CATC' to IEC60332 or equivalent.
- Ozone resistant.
- Oil resistant.
- Anti termite.
Sheathing layers can be Halogen Free Flame Retardant "HFFR", or Polyethylene '"PE'
Installation Conditions:
1.Air Temperature : 30 Deg.
2.Ground Temperature : 20 Deg
3.Soil Thermal Resistivity : 1.5 km/w
4.Depth of lay : 0.8 m
All dimensions have tolerance +-7 %
Marking
no. of cores x conductor size mm2 Cu/XLPE/PVC Voltage grade V Standard MADE IN QATAR QICC - Nexans Year Meters
Custom marking available
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Selling & delivery Information
Note: On request we are delivering three single core laid up cables on one drum
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania