ALSECURE® IEC LV, XLPE Insulation, HFFR 0.6/1KV

Products

12x1.5

Nexans ref. 2E002BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 12
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 480 kg/km
  • Nominal outer diameter: 18.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 23 A
  • Permissible current rating when buried: 21 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

12x2.5

Nexans ref. 2E003BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 12
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 640 kg/km
  • Nominal outer diameter: 19.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

19x1.5

Nexans ref. 2F002BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 19
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 655 kg/km
  • Nominal outer diameter: 20.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 23 A
  • Permissible current rating when buried: 21 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

19x2.5

Nexans ref. 2F003BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 19
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 880 kg/km
  • Nominal outer diameter: 22.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

1x10

Nexans ref. 21010BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 1
  • Conductor cross-section: 10 mm²
  • Approximate weight: 160 kg/km
  • Nominal outer diameter: 8.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 85 A
  • Permissible current rating when buried: 77 A
  • Voltage drop, 3 conductors: 3.6 V/A.km

 

1x120

Nexans ref. 21120BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 1
  • Conductor cross-section: 120 mm²
  • Approximate weight: 1140 kg/km
  • Nominal outer diameter: 18.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 400 A
  • Permissible current rating when buried: 306 A
  • Voltage drop, 3 conductors: 0.38 V/A.km

 

1x150

Nexans ref. 21150BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 1
  • Conductor cross-section: 150 mm²
  • Approximate weight: 1400 kg/km
  • Nominal outer diameter: 20.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 464 A
  • Permissible current rating when buried: 343 A
  • Voltage drop, 3 conductors: 0.33 V/A.km

 

1x16

Nexans ref. 21016BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 1
  • Conductor cross-section: 16 mm²
  • Approximate weight: 220 kg/km
  • Nominal outer diameter: 9.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 113 A
  • Permissible current rating when buried: 100 A
  • Voltage drop, 3 conductors: 2.3 V/A.km

 

1x185

Nexans ref. 21185BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 1
  • Conductor cross-section: 185 mm²
  • Approximate weight: 1740 kg/km
  • Nominal outer diameter: 22.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
  • Permissible current rating in open air: 533 A
  • Permissible current rating when buried: 387 A
  • Voltage drop, 3 conductors: 0.28 V/A.km

 

1x240

Nexans ref. 21240BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 1
  • Conductor cross-section: 240 mm²
  • Approximate weight: 2250 kg/km
  • Nominal outer diameter: 25.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
  • Permissible current rating in open air: 634 A
  • Permissible current rating when buried: 448 A
  • Voltage drop, 3 conductors: 0.24 V/A.km

 

1x25

Nexans ref. 21025BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 1
  • Conductor cross-section: 25 mm²
  • Approximate weight: 330 kg/km
  • Nominal outer diameter: 11.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 135 A
  • Permissible current rating when buried: 129 A
  • Voltage drop, 3 conductors: 1.5 V/A.km

 

1x300

Nexans ref. 21300BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 1
  • Conductor cross-section: 300 mm²
  • Approximate weight: 2780 kg/km
  • Nominal outer diameter: 27.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
  • Permissible current rating in open air: 736 A
  • Permissible current rating when buried: 502 A
  • Voltage drop, 3 conductors: 0.21 V/A.km

 

1x35

Nexans ref. 21035BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 1
  • Conductor cross-section: 35 mm²
  • Approximate weight: 425 kg/km
  • Nominal outer diameter: 12.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 169 A
  • Permissible current rating when buried: 155 A
  • Voltage drop, 3 conductors: 1.1 V/A.km

 

1x400

Nexans ref. 21400BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 1
  • Conductor cross-section: 400 mm²
  • Approximate weight: 3530 kg/km
  • Nominal outer diameter: 31.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
  • Permissible current rating in open air: 868 A
  • Permissible current rating when buried: 717 A
  • Voltage drop, 3 conductors: 0.18 V/A.km

 

1x50

Nexans ref. 21050BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 1
  • Conductor cross-section: 50 mm²
  • Approximate weight: 480 kg/km
  • Nominal outer diameter: 13.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 216 A
  • Permissible current rating when buried: 183 A
  • Voltage drop, 3 conductors: 0.83 V/A.km

 

1x500

Nexans ref. 21500BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 1
  • Conductor cross-section: 500 mm²
  • Approximate weight: 4570 kg/km
  • Nominal outer diameter: 35.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0366 Ohm/km
  • Permissible current rating in open air: 896 A
  • Permissible current rating when buried: 539 A
  • Voltage drop, 3 conductors: 0.16 V/A.km

 

1x630

Nexans ref. 21630BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 1
  • Conductor cross-section: 630 mm²
  • Approximate weight: 5810 kg/km
  • Nominal outer diameter: 39.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0283 Ohm/km
  • Permissible current rating in open air: 1035 A
  • Permissible current rating when buried: 678 A
  • Voltage drop, 3 conductors: 0.15 V/A.km

 

1x70

Nexans ref. 21070BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 1
  • Conductor cross-section: 70 mm²
  • Approximate weight: 670 kg/km
  • Nominal outer diameter: 15.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 279 A
  • Permissible current rating when buried: 225 A
  • Voltage drop, 3 conductors: 0.6 V/A.km

 

1x800

Nexans ref. 21800BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 1
  • Conductor cross-section: 800 mm²
  • Approximate weight: 7375 kg/km
  • Nominal outer diameter: 43.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0221 Ohm/km
  • Permissible current rating in open air: 1246 A
  • Permissible current rating when buried: 726 A
  • Voltage drop, 3 conductors: 0.14 V/A.km

 

1x95

Nexans ref. 21095BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 1
  • Conductor cross-section: 95 mm²
  • Approximate weight: 920 kg/km
  • Nominal outer diameter: 16.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 342 A
  • Permissible current rating when buried: 270 A
  • Voltage drop, 3 conductors: 0.46 V/A.km

 

24x1.5

Nexans ref. 2I002BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 24
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 860 kg/km
  • Nominal outer diameter: 23.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 23 A
  • Permissible current rating when buried: 21 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

24x2.5

Nexans ref. 2I003BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 24
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 1150 kg/km
  • Nominal outer diameter: 26.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

2x1.5

Nexans ref. 22002BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 300 kg/km
  • Nominal outer diameter: 11.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 23 A
  • Permissible current rating when buried: 21 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

2x10

Nexans ref. 22010BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 10 mm²
  • Approximate weight: 440 kg/km
  • Nominal outer diameter: 16.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 75 A
  • Permissible current rating when buried: 65 A
  • Voltage drop, 3 conductors: 3.5 V/A.km

 

2x120

Nexans ref. 22120BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 120 mm²
  • Approximate weight: 3240 kg/km
  • Nominal outer diameter: 37.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 346 A
  • Permissible current rating when buried: 257 A
  • Voltage drop, 3 conductors: 0.37 V/A.km

 

2x150

Nexans ref. 22150BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 150 mm²
  • Approximate weight: 3960 kg/km
  • Nominal outer diameter: 41.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 399 A
  • Permissible current rating when buried: 287 A
  • Voltage drop, 3 conductors: 0.31 V/A.km

 

2x16

Nexans ref. 22016BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 16 mm²
  • Approximate weight: 570 kg/km
  • Nominal outer diameter: 18.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 100 A
  • Permissible current rating when buried: 84 A
  • Voltage drop, 3 conductors: 2.2 V/A.km

 

2x185

Nexans ref. 22185BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 185 mm²
  • Approximate weight: 4980 kg/km
  • Nominal outer diameter: 46.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
  • Permissible current rating in open air: 456 A
  • Permissible current rating when buried: 324 A
  • Voltage drop, 3 conductors: 0.27 V/A.km

 

2x2.5

Nexans ref. 22003BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 240 kg/km
  • Nominal outer diameter: 12.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

2x25

Nexans ref. 22025BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 25 mm²
  • Approximate weight: 840 kg/km
  • Nominal outer diameter: 21.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 127 A
  • Permissible current rating when buried: 107 A
  • Voltage drop, 3 conductors: 1.5 V/A.km

 

2x35

Nexans ref. 22035BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 35 mm²
  • Approximate weight: 1070 kg/km
  • Nominal outer diameter: 23.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 158 A
  • Permissible current rating when buried: 129 A
  • Voltage drop, 3 conductors: 1.1 V/A.km

 

2x4

Nexans ref. 22004BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 4 mm²
  • Approximate weight: 190 kg/km
  • Nominal outer diameter: 13.0 mm
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 42 A
  • Permissible current rating when buried: 39 A
  • Voltage drop, 3 conductors: 8.7 V/A.km

 

2x50

Nexans ref. 22050BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 50 mm²
  • Approximate weight: 1400 kg/km
  • Nominal outer diameter: 26.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 192 A
  • Permissible current rating when buried: 153 A
  • Voltage drop, 3 conductors: 0.81 V/A.km

 

2x6

Nexans ref. 22006BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 6 mm²
  • Approximate weight: 160 kg/km
  • Nominal outer diameter: 14.0 mm
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 54 A
  • Permissible current rating when buried: 49 A
  • Voltage drop, 3 conductors: 5.9 V/A.km

 

2x70

Nexans ref. 22070BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 70 mm²
  • Approximate weight: 1950 kg/km
  • Nominal outer diameter: 30.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 246 A
  • Permissible current rating when buried: 188 A
  • Voltage drop, 3 conductors: 0.58 V/A.km

 

2x95

Nexans ref. 22095BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 95 mm²
  • Approximate weight: 2610 kg/km
  • Nominal outer diameter: 33.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 298 A
  • Permissible current rating when buried: 226 A
  • Voltage drop, 3 conductors: 0.44 V/A.km

 

37x1.5

Nexans ref. 2M002BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 37
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 1130 kg/km
  • Nominal outer diameter: 26.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 23 A
  • Permissible current rating when buried: 21 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

37x2.5

Nexans ref. 2M003BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 37
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 1550 kg/km
  • Nominal outer diameter: 29.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

3x1.5

Nexans ref. 23002BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 3
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 180 kg/km
  • Nominal outer diameter: 12.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 23 A
  • Permissible current rating when buried: 21 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

3x10

Nexans ref. 23010BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 3
  • Conductor cross-section: 10 mm²
  • Approximate weight: 520 kg/km
  • Nominal outer diameter: 17.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 75 A
  • Permissible current rating when buried: 65 A
  • Voltage drop, 3 conductors: 3.5 V/A.km

 

3x120

Nexans ref. 23120BXZOUH30BD0

  • Conductor shape: Sector-shaped
  • Number of cores: 3
  • Conductor cross-section: 120 mm²
  • Approximate weight: 3430 kg/km
  • Nominal outer diameter: 33.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 346 A
  • Permissible current rating when buried: 257 A
  • Voltage drop, 3 conductors: 0.37 V/A.km

 

3x150

Nexans ref. 23150BXZOUH30BD0

  • Conductor shape: Sector-shaped
  • Number of cores: 3
  • Conductor cross-section: 150 mm²
  • Approximate weight: 4240 kg/km
  • Nominal outer diameter: 37.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 399 A
  • Permissible current rating when buried: 287 A
  • Voltage drop, 3 conductors: 0.31 V/A.km

 

3x16

Nexans ref. 23016BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 3
  • Conductor cross-section: 16 mm²
  • Approximate weight: 720 kg/km
  • Nominal outer diameter: 19.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 100 A
  • Permissible current rating when buried: 84 A
  • Voltage drop, 3 conductors: 2.2 V/A.km

 

3x185

Nexans ref. 23185BXZOUH30BD0

  • Conductor shape: Sector-shaped
  • Number of cores: 3
  • Conductor cross-section: 185 mm²
  • Approximate weight: 5250 kg/km
  • Nominal outer diameter: 41.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
  • Permissible current rating in open air: 456 A
  • Permissible current rating when buried: 324 A
  • Voltage drop, 3 conductors: 0.27 V/A.km

 

3x2.5

Nexans ref. 23003BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 3
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 230 kg/km
  • Nominal outer diameter: 13.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

3x240

Nexans ref. 23240BXZOUH30BD0

  • Conductor shape: Sector-shaped
  • Number of cores: 3
  • Conductor cross-section: 240 mm²
  • Approximate weight: 6730 kg/km
  • Nominal outer diameter: 45.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
  • Permissible current rating in open air: 538 A
  • Permissible current rating when buried: 375 A
  • Voltage drop, 3 conductors: 0.23 V/A.km

 

3x25

Nexans ref. 23025BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 3
  • Conductor cross-section: 25 mm²
  • Approximate weight: 1060 kg/km
  • Nominal outer diameter: 22.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 127 A
  • Permissible current rating when buried: 107 A
  • Voltage drop, 3 conductors: 1.5 V/A.km

 

3x300

Nexans ref. 23300BXZOUH30BD0

  • Conductor shape: Sector-shaped
  • Number of cores: 3
  • Conductor cross-section: 300 mm²
  • Approximate weight: 8450 kg/km
  • Nominal outer diameter: 51.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
  • Permissible current rating in open air: 621 A
  • Permissible current rating when buried: 419 A
  • Voltage drop, 3 conductors: 0.2 V/A.km

 

3x35

Nexans ref. 23035BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 3
  • Conductor cross-section: 35 mm²
  • Approximate weight: 1380 kg/km
  • Nominal outer diameter: 25.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 158 A
  • Permissible current rating when buried: 129 A
  • Voltage drop, 3 conductors: 1.1 V/A.km

 

3x4

Nexans ref. 23004BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 3
  • Conductor cross-section: 4 mm²
  • Approximate weight: 290 kg/km
  • Nominal outer diameter: 14.0 mm
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 42 A
  • Permissible current rating when buried: 39 A
  • Voltage drop, 3 conductors: 8.7 V/A.km

 

3x400

Nexans ref. 23400BXZOUH30BD0

  • Conductor shape: Sector-shaped
  • Number of cores: 3
  • Conductor cross-section: 400 mm²
  • Approximate weight: 10800 kg/km
  • Nominal outer diameter: 58.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
  • Permissible current rating in open air: 765 A
  • Permissible current rating when buried: 468 A
  • Voltage drop, 3 conductors: 0.18 V/A.km

 

3x50

Nexans ref. 23050BXZOUH30BD0

  • Conductor shape: Sector-shaped
  • Number of cores: 3
  • Conductor cross-section: 50 mm²
  • Approximate weight: 1435 kg/km
  • Nominal outer diameter: 23.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 192 A
  • Permissible current rating when buried: 153 A
  • Voltage drop, 3 conductors: 0.81 V/A.km

 

3x6

Nexans ref. 23006BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 3
  • Conductor cross-section: 6 mm²
  • Approximate weight: 370 kg/km
  • Nominal outer diameter: 15.0 mm
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 54 A
  • Permissible current rating when buried: 49 A
  • Voltage drop, 3 conductors: 5.9 V/A.km

 

3x70

Nexans ref. 23070BXZOUH30BD0

  • Conductor shape: Sector-shaped
  • Number of cores: 3
  • Conductor cross-section: 70 mm²
  • Approximate weight: 2020 kg/km
  • Nominal outer diameter: 27.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 246 A
  • Permissible current rating when buried: 188 A
  • Voltage drop, 3 conductors: 0.58 V/A.km

 

3x95

Nexans ref. 23095BXZOUH30BD0

  • Conductor shape: Sector-shaped
  • Number of cores: 3
  • Conductor cross-section: 95 mm²
  • Approximate weight: 2745 kg/km
  • Nominal outer diameter: 30.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 298 A
  • Permissible current rating when buried: 226 A
  • Voltage drop, 3 conductors: 0.44 V/A.km

 

4x1.5

Nexans ref. 24002BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 4
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 210 kg/km
  • Nominal outer diameter: 13.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 23 A
  • Permissible current rating when buried: 21 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

4x10

Nexans ref. 24010BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 4
  • Conductor cross-section: 10 mm²
  • Approximate weight: 635 kg/km
  • Nominal outer diameter: 18.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 75 A
  • Permissible current rating when buried: 65 A
  • Voltage drop, 3 conductors: 3.5 V/A.km

 

4x120

Nexans ref. 24120BXZOUH30BD0

  • Conductor shape: Sector-shaped
  • Number of cores: 4
  • Conductor cross-section: 120 mm²
  • Approximate weight: 4480 kg/km
  • Nominal outer diameter: 37.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 346 A
  • Permissible current rating when buried: 257 A
  • Voltage drop, 3 conductors: 0.37 V/A.km

 

4x150

Nexans ref. 24150BXZOUH30BD0

  • Conductor shape: Sector-shaped
  • Number of cores: 4
  • Conductor cross-section: 150 mm²
  • Approximate weight: 5530 kg/km
  • Nominal outer diameter: 41.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 399 A
  • Permissible current rating when buried: 287 A
  • Voltage drop, 3 conductors: 0.31 V/A.km

 

4x16

Nexans ref. 24016BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 4
  • Conductor cross-section: 16 mm²
  • Approximate weight: 890 kg/km
  • Nominal outer diameter: 20.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 100 A
  • Permissible current rating when buried: 84 A
  • Voltage drop, 3 conductors: 2.2 V/A.km

 

4x185

Nexans ref. 24185BXZOUH30BD0

  • Conductor shape: Sector-shaped
  • Number of cores: 4
  • Conductor cross-section: 185 mm²
  • Approximate weight: 6900 kg/km
  • Nominal outer diameter: 46.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
  • Permissible current rating in open air: 456 A
  • Permissible current rating when buried: 324 A
  • Voltage drop, 3 conductors: 0.27 V/A.km

 

4x2.5

Nexans ref. 24003BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 4
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 270 kg/km
  • Nominal outer diameter: 14.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

4x240

Nexans ref. 24240BXZOUH30BD0

  • Conductor shape: Sector-shaped
  • Number of cores: 4
  • Conductor cross-section: 240 mm²
  • Approximate weight: 8980 kg/km
  • Nominal outer diameter: 51.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
  • Permissible current rating in open air: 538 A
  • Permissible current rating when buried: 375 A
  • Voltage drop, 3 conductors: 0.23 V/A.km

 

4x25

Nexans ref. 24025BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 4
  • Conductor cross-section: 25 mm²
  • Approximate weight: 1330 kg/km
  • Nominal outer diameter: 24.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 127 A
  • Permissible current rating when buried: 107 A
  • Voltage drop, 3 conductors: 1.5 V/A.km

 

4x300

Nexans ref. 24300BXZOUH30BD0

  • Conductor shape: Sector-shaped
  • Number of cores: 4
  • Conductor cross-section: 300 mm²
  • Approximate weight: 11270 kg/km
  • Nominal outer diameter: 58.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
  • Permissible current rating in open air: 621 A
  • Permissible current rating when buried: 419 A
  • Voltage drop, 3 conductors: 0.2 V/A.km

 

4x35

Nexans ref. 24035BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 4
  • Conductor cross-section: 35 mm²
  • Approximate weight: 1730 kg/km
  • Nominal outer diameter: 27.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 158 A
  • Permissible current rating when buried: 129 A
  • Voltage drop, 3 conductors: 1.1 V/A.km

 

4x4

Nexans ref. 24004BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 4
  • Conductor cross-section: 4 mm²
  • Approximate weight: 350 kg/km
  • Nominal outer diameter: 15.0 mm
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 42 A
  • Permissible current rating when buried: 39 A
  • Voltage drop, 3 conductors: 8.7 V/A.km

 

4x400

Nexans ref. 24400BXZOUH30BD0

  • Conductor shape: Sector-shaped
  • Number of cores: 4
  • Conductor cross-section: 400 mm²
  • Approximate weight: 14370 kg/km
  • Nominal outer diameter: 65.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
  • Permissible current rating in open air: 765 A
  • Permissible current rating when buried: 468 A
  • Voltage drop, 3 conductors: 0.18 V/A.km

 

4x50

Nexans ref. 24050BXZOUH30BD0

  • Conductor shape: Sector-shaped
  • Number of cores: 4
  • Conductor cross-section: 50 mm²
  • Approximate weight: 1860 kg/km
  • Nominal outer diameter: 25.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 192 A
  • Permissible current rating when buried: 153 A
  • Voltage drop, 3 conductors: 0.81 V/A.km

 

4x6

Nexans ref. 24006BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 4
  • Conductor cross-section: 6 mm²
  • Approximate weight: 440 kg/km
  • Nominal outer diameter: 16.0 mm
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 54 A
  • Permissible current rating when buried: 49 A
  • Voltage drop, 3 conductors: 5.9 V/A.km

 

4x70

Nexans ref. 24070BXZOUH30BD0

  • Conductor shape: Sector-shaped
  • Number of cores: 4
  • Conductor cross-section: 70 mm²
  • Approximate weight: 2630 kg/km
  • Nominal outer diameter: 29.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 246 A
  • Permissible current rating when buried: 188 A
  • Voltage drop, 3 conductors: 0.58 V/A.km

 

4x95

Nexans ref. 24095BXZOUH30BD0

  • Conductor shape: Sector-shaped
  • Number of cores: 4
  • Conductor cross-section: 95 mm²
  • Approximate weight: 2610 kg/km
  • Nominal outer diameter: 33.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 298 A
  • Permissible current rating when buried: 226 A
  • Voltage drop, 3 conductors: 0.44 V/A.km

 

5x1.5

Nexans ref. 25002BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 250 kg/km
  • Nominal outer diameter: 13.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 23 A
  • Permissible current rating when buried: 21 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

5x10

Nexans ref. 25010BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 10 mm²
  • Approximate weight: 760 kg/km
  • Nominal outer diameter: 20.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 75 A
  • Permissible current rating when buried: 65 A
  • Voltage drop, 3 conductors: 3.5 V/A.km

 

5x16

Nexans ref. 25016BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 16 mm²
  • Approximate weight: 1090 kg/km
  • Nominal outer diameter: 22.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 100 A
  • Permissible current rating when buried: 84 A
  • Voltage drop, 3 conductors: 2.2 V/A.km

 

5x2.5

Nexans ref. 25003BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 310 kg/km
  • Nominal outer diameter: 15.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

5x25

Nexans ref. 25025BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 25 mm²
  • Approximate weight: 1630 kg/km
  • Nominal outer diameter: 27.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 127 A
  • Permissible current rating when buried: 107 A
  • Voltage drop, 3 conductors: 1.5 V/A.km

 

5x35

Nexans ref. 25035BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 35 mm²
  • Approximate weight: 2610 kg/km
  • Nominal outer diameter: 30.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 158 A
  • Permissible current rating when buried: 129 A
  • Voltage drop, 3 conductors: 1.1 V/A.km

 

5x4

Nexans ref. 25004BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 4 mm²
  • Approximate weight: 410 kg/km
  • Nominal outer diameter: 16.0 mm
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 42 A
  • Permissible current rating when buried: 39 A
  • Voltage drop, 3 conductors: 8.7 V/A.km

 

5x50

Nexans ref. 25050BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 50 mm²
  • Approximate weight: 2480 kg/km
  • Nominal outer diameter: 33.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 192 A
  • Permissible current rating when buried: 153 A
  • Voltage drop, 3 conductors: 0.81 V/A.km

 

5x6

Nexans ref. 25006BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 6 mm²
  • Approximate weight: 530 kg/km
  • Nominal outer diameter: 17.0 mm
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 54 A
  • Permissible current rating when buried: 49 A
  • Voltage drop, 3 conductors: 5.9 V/A.km

 

5x70

Nexans ref. 25070BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 70 mm²
  • Approximate weight: 3480 kg/km
  • Nominal outer diameter: 39.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 246 A
  • Permissible current rating when buried: 188 A
  • Voltage drop, 3 conductors: 0.58 V/A.km

 

7x1.5

Nexans ref. 2C002BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 7
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 340 kg/km
  • Nominal outer diameter: 15.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 23 A
  • Permissible current rating when buried: 21 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

7x2.5

Nexans ref. 2C003BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 7
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 450 kg/km
  • Nominal outer diameter: 17.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

9x1.5

Nexans ref. 2K002BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 9
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 410 kg/km
  • Nominal outer diameter: 16.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 23 A
  • Permissible current rating when buried: 21 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

9x2.5

Nexans ref. 2K003BXZOUH30BD0

  • Conductor shape: Circular
  • Number of cores: 9
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 545 kg/km
  • Nominal outer diameter: 18.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

Description

Description

Standards

  • International
    IEC 60332-1; IEC 60502-1

Application


These power cables are used for electricity supply in low voltage installation systems.

They are well adapted to underground use in industrial applications where chemical and mechanical protections are needed (refinery areas, chemical plant…)

 

Design

 

  1. Conductor
    Stranded bare copper class 2 acc. to IEC 60228
     
  2. Insulation
    Cross Linked Polyethylene "XLPE"
     
  3. Inner Sheath or Bedding
    Lapped bedding or extruded HFFR 
     
  1. Outer Sheath 
    Halogen Free Flame retardant "HFFR".

      Options:

    - Flame retardant, Option "CAT A, CAT B, CAT C" to IEC60332 or equivalent.

    - Ozone resistant.

    - Oil resistant.

    - Anti termite

 Installation Conditions:

  1. Air Temperature : 30 Deg.
  2. Ground Temperature: 20 Deg.
  3. Soil Thermal Resistivity : 2.5 k.m/w
  4. Depth of lay : 0.7 m

 All dimensions have tolerance +- 7 %

Marking

no. of cores x conductor sizes mm2 Cu / XLPE / HFFR 600/1000 V  IEC 60502-1 MADE IN QATAR QICC-Nexans Year Meters

Custom marking available

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Insulation
XLPE (Cross-linked Polyethylene)
Inner sheath
Halogen free flame retardant
Armour type
Unarmoured
Outer sheath
Halogen free flame retardant
Colour
Black
Halogen free
Yes
Conductor flexibility
Stranded class 2

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Max. conductor temperature in service
90 °C
Short-circuit max. conductor temperature
250 °C
Bending factor when laying
19 (xD)
Bending factor when installed
10 (xD)
Smoke density
IEC 61034
Gases corrosivity
IEC 60754-2

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close