IEC MV, XLPE Insulation, CWS, Lead, AWA, PVC (1C)

Products

1x120

Nexans ref. 21120CXCVAB09DO0

  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 37.0 mm
  • Approximate weight: 3800 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x120

Nexans ref. 21120CXCVAB09EO0

  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 40.0 mm
  • Approximate weight: 3950 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x120

Nexans ref. 21120CXCVAB09GO0

  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 43.0 mm
  • Approximate weight: 4250 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x120

Nexans ref. 21120CXCVAB09HO0

  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 45.0 mm
  • Approximate weight: 4600 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x120

Nexans ref. 21120CXCVAB09JO0

  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 51.0 mm
  • Approximate weight: 5130 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x150

Nexans ref. 21150CXCVAB09DO0

  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 38.0 mm
  • Approximate weight: 4370 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x150

Nexans ref. 21150CXCVAB09EO0

  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 41.0 mm
  • Approximate weight: 4570 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x150

Nexans ref. 21150CXCVAB09GO0

  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 44.0 mm
  • Approximate weight: 4895 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x150

Nexans ref. 21150CXCVAB09HO0

  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 46.0 mm
  • Approximate weight: 5170 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x150

Nexans ref. 21150CXCVAB09JO0

  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 52.0 mm
  • Approximate weight: 5910 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x185

Nexans ref. 21185CXCVAB09DO0

  • Conductor cross-section: 185 mm²
  • Nominal outer diameter: 41.0 mm
  • Approximate weight: 5080 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x185

Nexans ref. 21185CXCVAB09EO0

  • Conductor cross-section: 185 mm²
  • Nominal outer diameter: 43.0 mm
  • Approximate weight: 5390 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x185

Nexans ref. 21185CXCVAB09GO0

  • Conductor cross-section: 185 mm²
  • Nominal outer diameter: 46.0 mm
  • Approximate weight: 5670 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x185

Nexans ref. 21185CXCVAB09HO0

  • Conductor cross-section: 185 mm²
  • Nominal outer diameter: 49.0 mm
  • Approximate weight: 5940 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x185

Nexans ref. 21185CXCVAB09JO0

  • Conductor cross-section: 185 mm²
  • Nominal outer diameter: 56.0 mm
  • Approximate weight: 7110 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x240

Nexans ref. 21240CXCVAB09DO0

  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 45.0 mm
  • Approximate weight: 5500 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x240

Nexans ref. 21240CXCVAB09EO0

  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 48.0 mm
  • Approximate weight: 5800 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x240

Nexans ref. 21240CXCVAB09GO0

  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 50.0 mm
  • Approximate weight: 6100 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x240

Nexans ref. 21240CXCVAB09HO0

  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 54.0 mm
  • Approximate weight: 6600 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x240

Nexans ref. 21240CXCVAB09JO0

  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 61.0 mm
  • Approximate weight: 7000 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x25

Nexans ref. 21025CXCVAB09DO0

  • Conductor cross-section: 25 mm²
  • Nominal outer diameter: 28.0 mm
  • Approximate weight: 1850 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x25

Nexans ref. 21025CXCVAB09EO0

  • Conductor cross-section: 25 mm²
  • Nominal outer diameter: 30.0 mm
  • Approximate weight: 2020 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x25

Nexans ref. 21025CXCVAB09GO0

  • Conductor cross-section: 25 mm²
  • Nominal outer diameter: 33.0 mm
  • Approximate weight: 2220 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x300

Nexans ref. 21300CXCVAB09DO0

  • Conductor cross-section: 300 mm²
  • Nominal outer diameter: 50.0 mm
  • Approximate weight: 6240 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x300

Nexans ref. 21300CXCVAB09EO0

  • Conductor cross-section: 300 mm²
  • Nominal outer diameter: 51.0 mm
  • Approximate weight: 6360 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x300

Nexans ref. 21300CXCVAB09GO0

  • Conductor cross-section: 300 mm²
  • Nominal outer diameter: 54.0 mm
  • Approximate weight: 6630 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x300

Nexans ref. 21300CXCVAB09HO0

  • Conductor cross-section: 300 mm²
  • Nominal outer diameter: 57.0 mm
  • Approximate weight: 7125 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x300

Nexans ref. 21300CXCVAB09JO0

  • Conductor cross-section: 300 mm²
  • Nominal outer diameter: 64.0 mm
  • Approximate weight: 7935 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x35

Nexans ref. 21035CXCVAB09DO0

  • Conductor cross-section: 35 mm²
  • Nominal outer diameter: 29.0 mm
  • Approximate weight: 2100 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x35

Nexans ref. 21035CXCVAB09EO0

  • Conductor cross-section: 35 mm²
  • Nominal outer diameter: 32.0 mm
  • Approximate weight: 2260 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x35

Nexans ref. 21035CXCVAB09GO0

  • Conductor cross-section: 35 mm²
  • Nominal outer diameter: 35.0 mm
  • Approximate weight: 2520 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x35

Nexans ref. 21035CXCVAB09HO0

  • Conductor cross-section: 35 mm²
  • Nominal outer diameter: 37.0 mm
  • Approximate weight: 2740 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x400

Nexans ref. 21400CXCVAB09DO0

  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: 55.0 mm
  • Approximate weight: 7815 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x400

Nexans ref. 21400CXCVAB09EO0

  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: 55.0 mm
  • Approximate weight: 7800 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x400

Nexans ref. 21400CXCVAB09GO0

  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: 61.0 mm
  • Approximate weight: 8475 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x400

Nexans ref. 21400CXCVAB09HO0

  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: 62.0 mm
  • Approximate weight: 8775 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x400

Nexans ref. 21400CXCVAB09JO0

  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: 68.0 mm
  • Approximate weight: 9405 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x50

Nexans ref. 21050CXCVAB09DO0

  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 32.0 mm
  • Approximate weight: 2430 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x50

Nexans ref. 21050CXCVAB09EO0

  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 34.0 mm
  • Approximate weight: 2600 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x50

Nexans ref. 21050CXCVAB09GO0

  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 36.0 mm
  • Approximate weight: 2860 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x50

Nexans ref. 21050CXCVAB09HO0

  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 38.0 mm
  • Approximate weight: 3100 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x50

Nexans ref. 21050CXCVAB09JO0

  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 44.0 mm
  • Approximate weight: 4000 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x500

Nexans ref. 21500CXCVAB09DO0

  • Conductor cross-section: 500 mm²
  • Nominal outer diameter: 59.0 mm
  • Approximate weight: 9840 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x500

Nexans ref. 21500CXCVAB09EO0

  • Conductor cross-section: 500 mm²
  • Nominal outer diameter: 61.0 mm
  • Approximate weight: 9900 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x500

Nexans ref. 21500CXCVAB09GO0

  • Conductor cross-section: 500 mm²
  • Nominal outer diameter: 63.0 mm
  • Approximate weight: 10155 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x500

Nexans ref. 21500CXCVAB09HO0

  • Conductor cross-section: 500 mm²
  • Nominal outer diameter: 65.0 mm
  • Approximate weight: 10500 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x500

Nexans ref. 21500CXCVAB09JO0

  • Conductor cross-section: 500 mm²
  • Nominal outer diameter: 72.0 mm
  • Approximate weight: 11325 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x630

Nexans ref. 21630CXCVAB09DO0

  • Conductor cross-section: 630 mm²
  • Nominal outer diameter: 64.0 mm
  • Approximate weight: 11925 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x630

Nexans ref. 21630CXCVAB09EO0

  • Conductor cross-section: 630 mm²
  • Nominal outer diameter: 65.0 mm
  • Approximate weight: 12000 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x630

Nexans ref. 21630CXCVAB09GO0

  • Conductor cross-section: 630 mm²
  • Nominal outer diameter: 68.0 mm
  • Approximate weight: 12270 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x630

Nexans ref. 21630CXCVAB09HO0

  • Conductor cross-section: 630 mm²
  • Nominal outer diameter: 70.0 mm
  • Approximate weight: 12600 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x630

Nexans ref. 21630CXCVAB09JO0

  • Conductor cross-section: 630 mm²
  • Nominal outer diameter: 76.0 mm
  • Approximate weight: 13575 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x70

Nexans ref. 21070CXCVAB09DO0

  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: 34.0 mm
  • Approximate weight: 2950 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x70

Nexans ref. 21070CXCVAB09EO0

  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: 35.0 mm
  • Approximate weight: 3140 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x70

Nexans ref. 21070CXCVAB09GO0

  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: 38.0 mm
  • Approximate weight: 3420 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x70

Nexans ref. 21070CXCVAB09HO0

  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: 41.0 mm
  • Approximate weight: 3660 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x70

Nexans ref. 21070CXCVAB09JO0

  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: 46.0 mm
  • Approximate weight: 4400 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x800

Nexans ref. 21800CXCVAB09DO0

  • Conductor cross-section: 800 mm²
  • Nominal outer diameter: 70.0 mm
  • Approximate weight: 14663 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x800

Nexans ref. 21800CXCVAB09EO0

  • Conductor cross-section: 800 mm²
  • Nominal outer diameter: 70.0 mm
  • Approximate weight: 14715 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x800

Nexans ref. 21800CXCVAB09GO0

  • Conductor cross-section: 800 mm²
  • Nominal outer diameter: 74.0 mm
  • Approximate weight: 15150 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x800

Nexans ref. 21800CXCVAB09HO0

  • Conductor cross-section: 800 mm²
  • Nominal outer diameter: 76.0 mm
  • Approximate weight: 15495 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x800

Nexans ref. 21800CXCVAB09JO0

  • Conductor cross-section: 800 mm²
  • Nominal outer diameter: 82.0 mm
  • Approximate weight: 16350 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

1x95

Nexans ref. 21095CXCVAB09DO0

  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 35.0 mm
  • Approximate weight: 3550 kg/km
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

1x95

Nexans ref. 21095CXCVAB09EO0

  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 37.0 mm
  • Approximate weight: 3760 kg/km
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

1x95

Nexans ref. 21095CXCVAB09GO0

  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 41.0 mm
  • Approximate weight: 4020 kg/km
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

1x95

Nexans ref. 21095CXCVAB09HO0

  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 43.0 mm
  • Approximate weight: 4380 kg/km
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

1x95

Nexans ref. 21095CXCVAB09JO0

  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 49.0 mm
  • Approximate weight: 5200 kg/km
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

Description

Description

Standards

  • International
    IEC 60332-1; IEC 60502-2

Application

These power cables are used for electricity supply in medium voltage installation system. They are well adapted to underground use in industrial application where chemical and mechanical protections are needed.
This group is complying with IEC 60502-2 or BS 6622.
 

Design

1. Conductor

Stranded bare copper class 2 acc. to IEC 60228 or equivalent

2. Insulation

Triple extruded Inner semi conductive layer  - Cross Linked Polyethylene 'XLPE' - Outer semi conductive layer

3. Metalic Screen

Copper wire screen with open helix copper tape

4. Metalic Sheath

Extruded Lead 

5. Armour

Aluminum Wire Armour "AWA"

6. Outer Sheath

Polyvinyl Chloride 'PVC'

 Options :

      - Flame retardant : 'CAT A, CAT B, CATC' to IEC60332 or equivalent.

      - Ozone resistant.

      - Oil resistant.

      - Anti termite.

Sheathing layers can be Halogen Free Flame Retardant "HFFR", or Polyethylene '"PE'


Installation Conditions:

1.Air Temperature : 30 Deg.

2.Ground Temperature : 20 Deg

3.Soil Thermal Resistivity : 1.5 km/w

4.Depth of lay : 0.8 m

 All dimensions have tolerance +-7 %

Marking

 no. of cores x  conductor size mm2  Cu/XLPE/LS/AWA/PVC  Voltage grade   Standard  MADE IN QATAR  QICC - Nexans  Year  Meters

Custom marking available

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor flexibility
Stranded class 2
Conductor shape
Circular compacted
Material of the inner semi-conductor
Semi-conducting compound
Insulation
XLPE (Cross-linked Polyethylene)
Material of the external semi-conductor
Semi-conducting compound
Screen
Copper wire + copper tape
Inner sheath
PVC
Lead Sheath
Yes
Separator
Tape or sheath
Armour type
Aluminium Wire
Outer sheath
PVC compound
Sheath colour
Black

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

Max. conductor temperature in service
90 °C
Flame retardant
IEC 60332-1
Bending factor when laying
30 (xD)
Bending factor when installed
15 (xD)
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Selling & delivery Information


Note: On request we are delivering three single core laid up cables on one drum

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close