Multi-core XLPE-insulated cables with PVC sheath
Read more3x120
Nexans ref. 23120CXCVSB09DD0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 63.0 mm
- Approximate weight: 7820 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x120
Nexans ref. 23120CXCVSB09ED0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 67.0 mm
- Approximate weight: 8330 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x120
Nexans ref. 23120CXCVSB09GD0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 72.0 mm
- Approximate weight: 9030 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x120
Nexans ref. 23120CXCVSB09HD0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 77.0 mm
- Approximate weight: 9670 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x120
Nexans ref. 23120CXCVSB09JD0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 89.0 mm
- Approximate weight: 12300 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x150
Nexans ref. 23150CXCVSB09DD0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 66.0 mm
- Approximate weight: 8970 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x150
Nexans ref. 23150CXCVSB09ED0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 70.0 mm
- Approximate weight: 9520 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x150
Nexans ref. 23150CXCVSB09GD0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 75.0 mm
- Approximate weight: 10160 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x150
Nexans ref. 23150CXCVSB09HD0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 82.0 mm
- Approximate weight: 11895 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x150
Nexans ref. 23150CXCVSB09JD0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 92.0 mm
- Approximate weight: 13600 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x185
Nexans ref. 23185CXCVSB09DD0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 70.0 mm
- Approximate weight: 10365 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x185
Nexans ref. 23185CXCVSB09ED0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 75.0 mm
- Approximate weight: 10920 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x185
Nexans ref. 23185CXCVSB09GD0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 82.0 mm
- Approximate weight: 12680 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x185
Nexans ref. 23185CXCVSB09HD0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 86.0 mm
- Approximate weight: 13415 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x185
Nexans ref. 23185CXCVSB09JD0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 96.0 mm
- Approximate weight: 15150 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x240
Nexans ref. 23240CXCVSB09DD0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 76.0 mm
- Approximate weight: 12445 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x240
Nexans ref. 23240CXCVSB09ED0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 82.0 mm
- Approximate weight: 14030 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x240
Nexans ref. 23240CXCVSB09GD0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 87.0 mm
- Approximate weight: 14850 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x240
Nexans ref. 23240CXCVSB09HD0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 91.0 mm
- Approximate weight: 15610 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x240
Nexans ref. 23240CXCVSB09JD0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 102.0 mm
- Approximate weight: 17320 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x25
Nexans ref. 23025CXCVSB09DD0
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 44.0 mm
- Approximate weight: 3270 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x25
Nexans ref. 23025CXCVSB09ED0
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 50.0 mm
- Approximate weight: 4030 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x25
Nexans ref. 23025CXCVSB09GD0
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 55.0 mm
- Approximate weight: 4650 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x300
Nexans ref. 23300CXCVSB09DD0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 87.0 mm
- Approximate weight: 16290 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x300
Nexans ref. 23300CXCVSB09ED0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 90.0 mm
- Approximate weight: 16800 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x300
Nexans ref. 23300CXCVSB09GD0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 95.0 mm
- Approximate weight: 17600 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x300
Nexans ref. 23300CXCVSB09HD0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 98.0 mm
- Approximate weight: 18240 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x300
Nexans ref. 23300CXCVSB09JD0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 110.0 mm
- Approximate weight: 19830 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x35
Nexans ref. 23035CXCVSB09DD0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 47.0 mm
- Approximate weight: 3710 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x35
Nexans ref. 23035CXCVSB09ED0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 53.0 mm
- Approximate weight: 4600 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x35
Nexans ref. 23035CXCVSB09GD0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 58.0 mm
- Approximate weight: 5100 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x35
Nexans ref. 23035CXCVSB09HD0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 62.0 mm
- Approximate weight: 5710 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x400
Nexans ref. 23400CXCVSB09DD0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 94.0 mm
- Approximate weight: 19470 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x400
Nexans ref. 23400CXCVSB09ED0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 96.0 mm
- Approximate weight: 19790 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x400
Nexans ref. 23400CXCVSB09GD0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 101.0 mm
- Approximate weight: 20480 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x400
Nexans ref. 23400CXCVSB09HD0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 105.0 mm
- Approximate weight: 21130 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x400
Nexans ref. 23400CXCVSB09JD0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 116.0 mm
- Approximate weight: 22680 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x50
Nexans ref. 23050CXCVSB09DD0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 51.0 mm
- Approximate weight: 4740 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x50
Nexans ref. 23050CXCVSB09ED0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 55.0 mm
- Approximate weight: 5200 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x50
Nexans ref. 23050CXCVSB09GD0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 60.0 mm
- Approximate weight: 5730 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x50
Nexans ref. 23050CXCVSB09HD0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 65.0 mm
- Approximate weight: 6360 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x50
Nexans ref. 23050CXCVSB09JD0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 78.0 mm
- Approximate weight: 8680 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x70
Nexans ref. 23070CXCVSB09DD0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 56.0 mm
- Approximate weight: 5730 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x70
Nexans ref. 23070CXCVSB09ED0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 60.0 mm
- Approximate weight: 6180 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x70
Nexans ref. 23070CXCVSB09GD0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 65.0 mm
- Approximate weight: 6850 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x70
Nexans ref. 23070CXCVSB09HD0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 69.0 mm
- Approximate weight: 7415 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x70
Nexans ref. 23070CXCVSB09JD0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 82.0 mm
- Approximate weight: 10000 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x95
Nexans ref. 23095CXCVSB09DD0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 59.0 mm
- Approximate weight: 6780 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x95
Nexans ref. 23095CXCVSB09ED0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 64.0 mm
- Approximate weight: 7350 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x95
Nexans ref. 23095CXCVSB09GD0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 69.0 mm
- Approximate weight: 7970 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x95
Nexans ref. 23095CXCVSB09HD0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 73.0 mm
- Approximate weight: 8620 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x95
Nexans ref. 23095CXCVSB09JD0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 86.0 mm
- Approximate weight: 11180 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
Description
Description
Standards
-
InternationalIEC 60332-1; IEC 60502-2
-
NationalBS 6622
Application
These power cables are used for electricity supply in medium voltage installation system. They are well adapted to underground use in industrial application where chemical and mechanical protections are needed. This group is complying with IEC 60502-2 or BS 6622.
Design
1. Conductor
Stranded bare copper class 2 acc. to IEC 60228 or equivalent
2. Insulation
Triple extruded Inner semi conductive layer - Cross Linked Polyethylene 'XLPE' - Outer semi conductive layer
3. Metalic Screen
Copper wire screen with open helix copper tape
4. Inner Sheathing or Bedding
Extruded PVC
5. Armour
Galvanized Steel Wire Armour "SWA"
6. Outer Sheath
Polyvinyl Chloride 'PVC'
Options :
- Flame retardant : 'CAT A, CAT B, CATC' to IEC60332 or equivalent.
- Ozone resistant.
- Oil resistant.
- Anti termite.
Sheathing layers can be Halogen Free Flame Retardant "HFFR", or Polyethylene '"PE'
Installation Conditions:
1.Air Temperature : 30 Deg.
2.Ground Temperature : 20 Deg
3.Soil Thermal Resistivity : 1.5 km/w
4.Depth of lay : 0.8 m
All dimensions have tolerance +-7 %
Marking
no. of cores x conductor size mm2 Cu/XLPE/SWA/PVC Voltage grade V Standard MADE IN QATAR QICC - Nexans Year Meters
Custom marking available
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Selling & delivery Information
Note: On request we are delivering three single core laid up cables on one drum
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania