IEC LV, XLPE Insulation, Lead, SWA, PVC 0.6/1 kV

Products

10x1.5

Nexans ref. 2D002BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 10
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 2898 kg/km
  • Nominal outer diameter: 26.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 23 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

10x2.5

Nexans ref. 2D003BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 10
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 3565 kg/km
  • Nominal outer diameter: 28.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

12x1.5

Nexans ref. 2E002BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 12
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 2300 kg/km
  • Nominal outer diameter: 25.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 23 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

12x2.5

Nexans ref. 2E003BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 12
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 2875 kg/km
  • Nominal outer diameter: 27.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

19x1.5

Nexans ref. 2F002BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 19
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 2990 kg/km
  • Nominal outer diameter: 28.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 23 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

19x2.5

Nexans ref. 2F003BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 19
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 4186 kg/km
  • Nominal outer diameter: 32.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

24x1.5

Nexans ref. 2I002BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 24
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 4025 kg/km
  • Nominal outer diameter: 32.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 23 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

24x2.5

Nexans ref. 2I003BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 24
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 5106 kg/km
  • Nominal outer diameter: 35.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

2x1.5

Nexans ref. 22002BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 989 kg/km
  • Nominal outer diameter: 18.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 23 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

2x10

Nexans ref. 22010BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 10 mm²
  • Approximate weight: 2277 kg/km
  • Nominal outer diameter: 24.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 78 A
  • Permissible current rating when buried: 65 A
  • Voltage drop, 3 conductors: 3.5 V/A.km

 

2x120

Nexans ref. 22120BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 120 mm²
  • Approximate weight: 11155 kg/km
  • Nominal outer diameter: 44.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 353 A
  • Permissible current rating when buried: 257 A
  • Voltage drop, 3 conductors: 0.37 V/A.km

 

2x150

Nexans ref. 22150BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 150 mm²
  • Approximate weight: 13225 kg/km
  • Nominal outer diameter: 48.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 406 A
  • Permissible current rating when buried: 287 A
  • Voltage drop, 3 conductors: 0.3 V/A.km

 

2x16

Nexans ref. 22016BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 16 mm²
  • Approximate weight: 3358 kg/km
  • Nominal outer diameter: 27.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 99 A
  • Permissible current rating when buried: 84 A
  • Voltage drop, 3 conductors: 2.2 V/A.km

 

2x185

Nexans ref. 22185BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 185 mm²
  • Approximate weight: 17181 kg/km
  • Nominal outer diameter: 54.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
  • Permissible current rating in open air: 463 A
  • Permissible current rating when buried: 324 A
  • Voltage drop, 3 conductors: 0.26 V/A.km

 

2x2.5

Nexans ref. 22003BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 1219 kg/km
  • Nominal outer diameter: 19.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

2x25

Nexans ref. 22025BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 25 mm²
  • Approximate weight: 3496 kg/km
  • Nominal outer diameter: 27.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 131 A
  • Permissible current rating when buried: 107 A
  • Voltage drop, 3 conductors: 1.65 V/A.km

 

2x35

Nexans ref. 22035BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 35 mm²
  • Approximate weight: 4876 kg/km
  • Nominal outer diameter: 31.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 162 A
  • Permissible current rating when buried: 129 A
  • Voltage drop, 3 conductors: 1.15 V/A.km

 

2x4

Nexans ref. 22004BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 4 mm²
  • Approximate weight: 1472 kg/km
  • Nominal outer diameter: 20.0 mm
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 44 A
  • Permissible current rating when buried: 39 A
  • Voltage drop, 3 conductors: 8.7 V/A.km

 

2x50

Nexans ref. 22050BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 50 mm²
  • Approximate weight: 6118 kg/km
  • Nominal outer diameter: 33.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 197 A
  • Permissible current rating when buried: 153 A
  • Voltage drop, 3 conductors: 0.89 V/A.km

 

2x6

Nexans ref. 22006BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 6 mm²
  • Approximate weight: 1748 kg/km
  • Nominal outer diameter: 21.0 mm
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 56 A
  • Permissible current rating when buried: 49 A
  • Voltage drop, 3 conductors: 5.9 V/A.km

 

2x70

Nexans ref. 22070BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 70 mm²
  • Approximate weight: 6877 kg/km
  • Nominal outer diameter: 36.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 251 A
  • Permissible current rating when buried: 188 A
  • Voltage drop, 3 conductors: 0.6 V/A.km

 

2x95

Nexans ref. 22095BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 2
  • Conductor cross-section: 95 mm²
  • Approximate weight: 9315 kg/km
  • Nominal outer diameter: 41.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 304 A
  • Permissible current rating when buried: 226 A
  • Voltage drop, 3 conductors: 0.45 V/A.km

 

37x1.5

Nexans ref. 2M002BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 37
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 5198 kg/km
  • Nominal outer diameter: 35.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 23 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

37x2.5

Nexans ref. 2M003BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 37
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 8211 kg/km
  • Nominal outer diameter: 40.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

3x1.5

Nexans ref. 23002BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 3
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 1058 kg/km
  • Nominal outer diameter: 19.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 23 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

3x10

Nexans ref. 23010BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 3
  • Conductor cross-section: 10 mm²
  • Approximate weight: 3013 kg/km
  • Nominal outer diameter: 26.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 78 A
  • Permissible current rating when buried: 65 A
  • Voltage drop, 3 conductors: 3.5 V/A.km

 

3x120

Nexans ref. 23120BXZVSB09BO0

  • Conductor shape: Sector-shaped
  • Number of cores: 3
  • Conductor cross-section: 120 mm²
  • Approximate weight: 15318 kg/km
  • Nominal outer diameter: 50.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 353 A
  • Permissible current rating when buried: 257 A
  • Voltage drop, 3 conductors: 0.37 V/A.km

 

3x150

Nexans ref. 23150BXZVSB09BO0

  • Conductor shape: Sector-shaped
  • Number of cores: 3
  • Conductor cross-section: 150 mm²
  • Approximate weight: 19550 kg/km
  • Nominal outer diameter: 56.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 406 A
  • Permissible current rating when buried: 287 A
  • Voltage drop, 3 conductors: 0.3 V/A.km

 

3x16

Nexans ref. 23016BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 3
  • Conductor cross-section: 16 mm²
  • Approximate weight: 3979 kg/km
  • Nominal outer diameter: 28.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 99 A
  • Permissible current rating when buried: 84 A
  • Voltage drop, 3 conductors: 2.2 V/A.km

 

3x185

Nexans ref. 23185BXZVSB09BO0

  • Conductor shape: Sector-shaped
  • Number of cores: 3
  • Conductor cross-section: 185 mm²
  • Approximate weight: 23529 kg/km
  • Nominal outer diameter: 61.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
  • Permissible current rating in open air: 463 A
  • Permissible current rating when buried: 324 A
  • Voltage drop, 3 conductors: 0.26 V/A.km

 

3x2.5

Nexans ref. 23003BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 3
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 1334 kg/km
  • Nominal outer diameter: 20.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

3x240

Nexans ref. 23240BXZVSB09BO0

  • Conductor shape: Sector-shaped
  • Number of cores: 3
  • Conductor cross-section: 240 mm²
  • Approximate weight: 29394 kg/km
  • Nominal outer diameter: 66.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
  • Permissible current rating in open air: 546 A
  • Permissible current rating when buried: 375 A
  • Voltage drop, 3 conductors: 0.21 V/A.km

 

3x25

Nexans ref. 23025BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 3
  • Conductor cross-section: 25 mm²
  • Approximate weight: 5290 kg/km
  • Nominal outer diameter: 31.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 131 A
  • Permissible current rating when buried: 107 A
  • Voltage drop, 3 conductors: 1.65 V/A.km

 

3x300

Nexans ref. 23300BXZVSB09BO0

  • Conductor shape: Sector-shaped
  • Number of cores: 3
  • Conductor cross-section: 300 mm²
  • Approximate weight: 35466 kg/km
  • Nominal outer diameter: 72.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
  • Permissible current rating in open air: 628 A
  • Permissible current rating when buried: 419 A
  • Voltage drop, 3 conductors: 0.18 V/A.km

 

3x35

Nexans ref. 23035BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 3
  • Conductor cross-section: 35 mm²
  • Approximate weight: 6532 kg/km
  • Nominal outer diameter: 34.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 162 A
  • Permissible current rating when buried: 129 A
  • Voltage drop, 3 conductors: 1.15 V/A.km

 

3x4

Nexans ref. 23004BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 3
  • Conductor cross-section: 4 mm²
  • Approximate weight: 1656 kg/km
  • Nominal outer diameter: 21.0 mm
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 44 A
  • Permissible current rating when buried: 39 A
  • Voltage drop, 3 conductors: 8.7 V/A.km

 

3x400

Nexans ref. 23400BXZVSB09BO0

  • Conductor shape: Sector-shaped
  • Number of cores: 3
  • Conductor cross-section: 400 mm²
  • Approximate weight: 44321 kg/km
  • Nominal outer diameter: 80.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
  • Permissible current rating in open air: 731 A
  • Permissible current rating when buried: 439 A
  • Voltage drop, 3 conductors: 0.17 V/A.km

 

3x50

Nexans ref. 23050BXZVSB09BO0

  • Conductor shape: Sector-shaped
  • Number of cores: 3
  • Conductor cross-section: 50 mm²
  • Approximate weight: 8142 kg/km
  • Nominal outer diameter: 38.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 197 A
  • Permissible current rating when buried: 153 A
  • Voltage drop, 3 conductors: 0.89 V/A.km

 

3x6

Nexans ref. 23006BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 3
  • Conductor cross-section: 6 mm²
  • Approximate weight: 1978 kg/km
  • Nominal outer diameter: 23.0 mm
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 56 A
  • Permissible current rating when buried: 49 A
  • Voltage drop, 3 conductors: 5.9 V/A.km

 

3x70

Nexans ref. 23070BXZVSB09BO0

  • Conductor shape: Sector-shaped
  • Number of cores: 3
  • Conductor cross-section: 70 mm²
  • Approximate weight: 9223 kg/km
  • Nominal outer diameter: 41.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 251 A
  • Permissible current rating when buried: 188 A
  • Voltage drop, 3 conductors: 0.6 V/A.km

 

3x95

Nexans ref. 23095BXZVSB09BO0

  • Conductor shape: Sector-shaped
  • Number of cores: 3
  • Conductor cross-section: 95 mm²
  • Approximate weight: 12673 kg/km
  • Nominal outer diameter: 47.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 304 A
  • Permissible current rating when buried: 226 A
  • Voltage drop, 3 conductors: 0.45 V/A.km

 

4x1.5

Nexans ref. 24002BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 4
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 1196 kg/km
  • Nominal outer diameter: 19.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 23 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

4x10

Nexans ref. 24010BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 4
  • Conductor cross-section: 10 mm²
  • Approximate weight: 3542 kg/km
  • Nominal outer diameter: 27.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 78 A
  • Permissible current rating when buried: 65 A
  • Voltage drop, 3 conductors: 3.5 V/A.km

 

4x120

Nexans ref. 24120BXZVSB09BO0

  • Conductor shape: Sector-shaped
  • Number of cores: 4
  • Conductor cross-section: 120 mm²
  • Approximate weight: 20792 kg/km
  • Nominal outer diameter: 57.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 353 A
  • Permissible current rating when buried: 257 A
  • Voltage drop, 3 conductors: 0.37 V/A.km

 

4x150

Nexans ref. 24150BXZVSB09BO0

  • Conductor shape: Sector-shaped
  • Number of cores: 4
  • Conductor cross-section: 150 mm²
  • Approximate weight: 24610 kg/km
  • Nominal outer diameter: 62.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 406 A
  • Permissible current rating when buried: 287 A
  • Voltage drop, 3 conductors: 0.3 V/A.km

 

4x16

Nexans ref. 24016BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 4
  • Conductor cross-section: 16 mm²
  • Approximate weight: 4600 kg/km
  • Nominal outer diameter: 31.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 99 A
  • Permissible current rating when buried: 84 A
  • Voltage drop, 3 conductors: 2.2 V/A.km

 

4x185

Nexans ref. 24185BXZVSB09BO0

  • Conductor shape: Sector-shaped
  • Number of cores: 4
  • Conductor cross-section: 185 mm²
  • Approximate weight: 29808 kg/km
  • Nominal outer diameter: 67.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
  • Permissible current rating in open air: 463 A
  • Permissible current rating when buried: 324 A
  • Voltage drop, 3 conductors: 0.26 V/A.km

 

4x2.5

Nexans ref. 24003BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 4
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 1518 kg/km
  • Nominal outer diameter: 21.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

4x240

Nexans ref. 24240BXZVSB09BO0

  • Conductor shape: Sector-shaped
  • Number of cores: 4
  • Conductor cross-section: 240 mm²
  • Approximate weight: 37605 kg/km
  • Nominal outer diameter: 74.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
  • Permissible current rating in open air: 546 A
  • Permissible current rating when buried: 375 A
  • Voltage drop, 3 conductors: 0.21 V/A.km

 

4x25

Nexans ref. 24025BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 4
  • Conductor cross-section: 25 mm²
  • Approximate weight: 6348 kg/km
  • Nominal outer diameter: 34.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 131 A
  • Permissible current rating when buried: 107 A
  • Voltage drop, 3 conductors: 1.65 V/A.km

 

4x300

Nexans ref. 24300BXZVSB09BO0

  • Conductor shape: Sector-shaped
  • Number of cores: 4
  • Conductor cross-section: 300 mm²
  • Approximate weight: 45540 kg/km
  • Nominal outer diameter: 80.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
  • Permissible current rating in open air: 628 A
  • Permissible current rating when buried: 419 A
  • Voltage drop, 3 conductors: 0.18 V/A.km

 

4x35

Nexans ref. 24035BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 4
  • Conductor cross-section: 35 mm²
  • Approximate weight: 7958 kg/km
  • Nominal outer diameter: 36.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 162 A
  • Permissible current rating when buried: 129 A
  • Voltage drop, 3 conductors: 1.15 V/A.km

 

4x4

Nexans ref. 24004BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 4
  • Conductor cross-section: 4 mm²
  • Approximate weight: 1863 kg/km
  • Nominal outer diameter: 23.0 mm
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 44 A
  • Permissible current rating when buried: 39 A
  • Voltage drop, 3 conductors: 8.7 V/A.km

 

4x400

Nexans ref. 24400BXZVSB09BO0

  • Conductor shape: Sector-shaped
  • Number of cores: 4
  • Conductor cross-section: 400 mm²
  • Approximate weight: 59616 kg/km
  • Nominal outer diameter: 92.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
  • Permissible current rating in open air: 731 A
  • Permissible current rating when buried: 439 A
  • Voltage drop, 3 conductors: 0.17 V/A.km

 

4x50

Nexans ref. 24050BXZVSB09BO0

  • Conductor shape: Sector-shaped
  • Number of cores: 4
  • Conductor cross-section: 50 mm²
  • Approximate weight: 10143 kg/km
  • Nominal outer diameter: 41.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 197 A
  • Permissible current rating when buried: 153 A
  • Voltage drop, 3 conductors: 0.89 V/A.km

 

4x6

Nexans ref. 24006BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 4
  • Conductor cross-section: 6 mm²
  • Approximate weight: 2656.5 kg/km
  • Nominal outer diameter: 25.0 mm
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 56 A
  • Permissible current rating when buried: 49 A
  • Voltage drop, 3 conductors: 5.9 V/A.km

 

4x70

Nexans ref. 24070BXZVSB09BO0

  • Conductor shape: Sector-shaped
  • Number of cores: 4
  • Conductor cross-section: 70 mm²
  • Approximate weight: 12535 kg/km
  • Nominal outer diameter: 47.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 251 A
  • Permissible current rating when buried: 188 A
  • Voltage drop, 3 conductors: 0.6 V/A.km

 

4x95

Nexans ref. 24095BXZVSB09BO0

  • Conductor shape: Sector-shaped
  • Number of cores: 4
  • Conductor cross-section: 95 mm²
  • Approximate weight: 15893 kg/km
  • Nominal outer diameter: 51.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 304 A
  • Permissible current rating when buried: 226 A
  • Voltage drop, 3 conductors: 0.45 V/A.km

 

5x1.5

Nexans ref. 25002BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 1380 kg/km
  • Nominal outer diameter: 20.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 23 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

5x10

Nexans ref. 25010BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 10 mm²
  • Approximate weight: 4094 kg/km
  • Nominal outer diameter: 29.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 78 A
  • Permissible current rating when buried: 65 A
  • Voltage drop, 3 conductors: 3.5 V/A.km

 

5x16

Nexans ref. 25016BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 16 mm²
  • Approximate weight: 6118 kg/km
  • Nominal outer diameter: 34.0 mm
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 99 A
  • Permissible current rating when buried: 84 A
  • Voltage drop, 3 conductors: 2.2 V/A.km

 

5x2.5

Nexans ref. 25003BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 1702 kg/km
  • Nominal outer diameter: 23.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

5x25

Nexans ref. 25025BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 25 mm²
  • Approximate weight: 8211 kg/km
  • Nominal outer diameter: 39.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 131 A
  • Permissible current rating when buried: 107 A
  • Voltage drop, 3 conductors: 1.65 V/A.km

 

5x35

Nexans ref. 25035BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 35 mm²
  • Approximate weight: 10212 kg/km
  • Nominal outer diameter: 42.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 162 A
  • Permissible current rating when buried: 129 A
  • Voltage drop, 3 conductors: 1.15 V/A.km

 

5x4

Nexans ref. 25004BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 4 mm²
  • Approximate weight: 2196.5 kg/km
  • Nominal outer diameter: 24.0 mm
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 44 A
  • Permissible current rating when buried: 39 A
  • Voltage drop, 3 conductors: 8.7 V/A.km

 

5x50

Nexans ref. 25050BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 50 mm²
  • Approximate weight: 14145 kg/km
  • Nominal outer diameter: 48.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 197 A
  • Permissible current rating when buried: 153 A
  • Voltage drop, 3 conductors: 0.89 V/A.km

 

5x6

Nexans ref. 25006BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 6 mm²
  • Approximate weight: 3059 kg/km
  • Nominal outer diameter: 26.0 mm
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 56 A
  • Permissible current rating when buried: 49 A
  • Voltage drop, 3 conductors: 5.9 V/A.km

 

5x70

Nexans ref. 25070BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 5
  • Conductor cross-section: 70 mm²
  • Approximate weight: 16054 kg/km
  • Nominal outer diameter: 54.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 251 A
  • Permissible current rating when buried: 188 A
  • Voltage drop, 3 conductors: 0.6 V/A.km

 

6x1.5

Nexans ref. 2B002BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 6
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 1909 kg/km
  • Nominal outer diameter: 23.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 23 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

6x2.5

Nexans ref. 2B003BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 6
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 2714 kg/km
  • Nominal outer diameter: 25.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

7x1.5

Nexans ref. 2C002BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 7
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 1426 kg/km
  • Nominal outer diameter: 21.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 23 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

7x2.5

Nexans ref. 2C003BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 7
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 2116 kg/km
  • Nominal outer diameter: 25.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

9x1.5

Nexans ref. 2K002BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 9
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 2024 kg/km
  • Nominal outer diameter: 24.0 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 23 A
  • Voltage drop, 3 conductors: 22.8 V/A.km

 

9x2.5

Nexans ref. 2K003BXZVSB09BO0

  • Conductor shape: Circular
  • Number of cores: 9
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 2461 kg/km
  • Nominal outer diameter: 26.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 30 A
  • Voltage drop, 3 conductors: 14.0 V/A.km

 

Description

Description

Standards

  • International
    IEC 60332-1; IEC 60502-1
  • National
    EEMUA Pub. N°133

Application


These power cables are used for electricity supply in low voltage installation systems.

They are well adapted to underground use in industrial applications where chemical and mechanical protections are needed (refinery areas, chemical plant…)

 

Design

 

  1. Conductor
    Stranded bare copper class 2 acc. to IEC 60228
     
  2. Insulation
    Cross Linked Polyethylene "XLPE"
     
  3. Inner Sheath or Bedding
    Lapped bedding or extruded PVC 
     
  4. Metalic Sheath 
    Extruded Lead sheath layer
     
  5. Armour
    Galvanized Steel Wire Armour "SWA"
  1. Outer Sheath 
    Polyvinyl Chloride "PVC"

      Options :

             - Flame retardant : "CAT A, CAT B, CAT C" to IEC60332 or equivalent.

             - Ozone resistant.

             - Oil resistant.

             - Anti termite.

 Installation Conditions:

  1. Air Temperature : 30 Deg.
  2. Ground Temperature: 20 Deg.
  3. Soil Thermal Resistivity : 2.5 k.m/w
  4. Depth of lay : 0.7 m

 All dimensions have tolerance +- 7 %

Marking

no. of cores x conductor sizes mm2 Cu / XLPE / Lead / SWA / PVC 600/1000 V IEC 60502-1 MADE IN QATAR QICC-Nexans Year Meters

Custom marking available

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Insulation
XLPE (Cross-linked Polyethylene)
Inner sheath
PVC
Lead Sheath
Yes
Armour type
Galvanized steel wires
Outer sheath
PVC
Colour
Black
Conductor flexibility
Stranded class 2
Halogen free
No

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Max. conductor temperature in service
90 °C
Short-circuit max. conductor temperature
250 °C
Bending factor when laying
20 (xD)
Bending factor when installed
10 (xD)

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close