Description
Standards
International : IEC 60332-1; IEC 60502-2Description
Application
These power cables are used for electricity supply in medium voltage installation system. They are well adapted to underground use in industrial application where chemical and mechanical protections are needed. This group is complying with IEC 60502-2.
Design
1. Conductor
Stranded bare copper class 2 acc. to IEC 60228 or equivalent
2. Insulation
Triple extruded Inner semi conductive layer - Cross Linked Polyethylene 'XLPE' - Outer semi conductive layer
3. Metalic Screen
Copper tape screen
4. Metal Sheath
Extruded Lead
5. Armour
Galvanized Steel Tape Armour "STA"
6. Outer Sheath
Polyvinyl Chloride 'PVC'
Options :
- Flame retardant : 'CAT A, CAT B, CATC' to IEC60332 or equivalent.
- Ozone resistant.
- Oil resistant.
- Anti termite.
Sheathing layers can be Halogen Free Flame Retardant "HFFR", or Polyethylene '"PE'
Installation Conditions:
1.Air Temperature : 30 Deg.
2.Ground Temperature : 20 Deg
3.Soil Thermal Resistivity : 1.5 km/w
4.Depth of lay : 0.8 m
All dimensions have tolerance +-7 %
Marking
no. of cores x conductor size mm2 Cu/XLPE/LS/STA/PVC Voltage grade V Standard MADE IN QATAR QICC - Nexans Year Meters
Custom marking available
Characteristics
Construction characteristics | |
---|---|
Conductor flexibility | Stranded class 2 |
Conductor shape | Circular compacted |
Material of the inner semi-conductor | Semi-conducting compound |
Insulation | XLPE (Cross-linked Polyethylene) |
Screen | Copper tape |
Inner sheath | PVC |
Lead Sheath | Yes |
Separator | Tape or sheath |
Armour type | Galvanized steel tapes |
Outer sheath | PVC compound |
Sheath colour | Black |
Dimensional characteristics | |
Number of cores | 3 |
Conductor cross-section | 25mm² |
Nominal outer diameter | 56.0mm |
Approximate weight | 7295kg/km |
Electrical characteristics | |
Rated Voltage Uo/U (Um) | 8.7 / 15 (17.5) kV |
Nominal phase capacitance | 0.17µF / km |
Voltage drop, 3 conductors | 0.84V/A.km |
Permissible current rating when buried | 129A |
Permissible current rating in open air | 143A |
Max. DC resistance of the conductor at 20°C | 0.727Ohm/km |
Mechanical characteristics | |
Mechanical resistance to impacts | Good |
Usage characteristics | |
Max. conductor temperature in service | 90°C |
Flame retardant | IEC 60332-1 |
Bending factor when laying | 40(xD) |
Bending factor when installed | 20(xD) |
Short-circuit max. conductor temperature | 250°C |